| Capacity | 80 L |
| Temperature Range | 5 to 80°C |
| Display Resolution | 0.1℃ |
| Temperature Stability | High ±0.5℃ Low ±1℃ |
| Temperature Uniformity | ±2℃ |
| Capacity | 150 L |
| Temperature Range | 5 to 80°C |
| Display Resolution | 0.1℃ |
| Temperature Stability | High ±0.5℃ Low ±1℃ |
| Temperature Uniformity | ±2℃ |
| Capacity | 250 L |
| Temperature Range | 5 to 80°C |
| Display Resolution | 0.1℃ |
| Temperature Stability | High ±0.5℃ Low ±1℃ |
| Temperature Uniformity | ±2℃ |
| Capacity | 500 L |
| Temperature Range | 5 to 80°C |
| Display Resolution | 0.1℃ |
| Temperature Stability | High ±0.5℃ Low ±1℃ |
| Temperature Uniformity | ±2℃ |
| Capacity | 800 L |
| Temperature Range | 5 to 80°C |
| Display Resolution | 0.1℃ |
| Temperature Stability | High ±0.5℃ Low ±1℃ |
| Temperature Uniformity | ±2℃ |
| Chamber Volume | 80 L |
| Temperature control range | 0 ~ 100°C |
| Temperature Fluctuation | ±0.5°C |
| Humidity Range | 20 ~ 98% RH |
| Humidity Stability | ±2% RH |
| Chamber Volume | 500L |
| Temperature Control Range | 0 to 65°C without illumination, 10 to 50°C with illumination |
| Temperature Stability | ±0.5 °C |
| Temperature Uniformity | ±2 °C |
| Humidity Range | 35 to 95%RH |
| Chamber Volume | 800L |
| Temperature Control Range | 0 to 65°C without illumination, 10 to 50°C with illumination |
| Temperature Stability | ±0.5 °C |
| Temperature Uniformity | ±2 °C |
| Humidity Range | 35 to 95%RH |
| Chamber Volume | 150 L |
| Temperature control range | 0 to 65℃ without illumination, 10 to 50℃ with illumination |
| Temperature Stability | ±0.5℃ |
| Temperature Uniformity | ±2℃ |
| Humidity Range | 35 to 95 % RH |
| Chamber Volume | 250 L |
| Temperature control range | 0 to 65℃ without illumination, 10 to 50℃ with illumination |
| Temperature Stability | ±0.5℃ |
| Temperature Uniformity | ±2℃ |
| Humidity Range | 35 to 95 % RH |
| Control system | Siemens PLC |
| Program function | 4 groups standard program built-in and 2 groups program can be se |
| Sample area | 930 cm2 |
| Sample surface temperature monitoring | Blackboard temperature automatic control by sensor |
| Spraying system | NO |
| Control system | Siemens PLC |
| Program function | 4 groups standard program built-in and 2 groups program can be se |
| Sample area | 930 cm2 |
| Sample surface temperature monitoring | Blackboard temperature automatic control by sensor |
| Spraying system | Yes |
| Temperature Range for Light cycle | 45℃ to 80℃ |
| Temperature Range for Condensation cycle | 40℃ to 60℃ |
| Light source type | UVA fluorescent ultraviolet lamp |
| Power | 20 W/pc, total 4 pcs |
| Wavelength range | Standard with UVA@ 340 nm |
| Temperature Range for Light cycle | 45℃ to 80℃ |
| Temperature Range for Condensation cycle | 40℃ to 60℃ |
| Light source type | UVA or UVB fluorescent ultraviolet lamp |
| Power | 40 W/pc, total 8 pcs |
| Wavelength range | Standard with UVA@340 nm Optional@351 nm or UVB@313 nm |
| Temperature Range for Light cycle | 45℃ to 80℃ |
| Temperature Range for Condensation cycle | 40℃ to 60℃ |
| Light source type | UVA or UVB fluorescent ultraviolet lamp |
| Power | 40 W/pc, total 8 pcs |
| Wavelength range | Standard with UVA@340 nm Optional@351 nm or UVB@313 nm |
| Spray type | Continuous / Periodic |
| Temperature range | 35℃ to 55℃ |
| Temperature fluctuation | ≤±0.5℃ |
| Temperature uniformity | 2℃ |
| Humidity range | 95 to 98% RH |
| Spray type | Continuous / Periodic |
| Temperature range | 35℃ to 55℃ |
| Temperature fluctuation | ≤±0.5℃ |
| Temperature uniformity | 2℃ |
| Humidity range | 95 to 98 % RH |
| Spray type | Continuous / Periodic |
| Temperature range | 35℃ to 55℃ |
| Temperature fluctuation | ≤±0.5℃ |
| Temperature uniformity | 2℃ |
| Humidity range | 95 to 98 % RH |
| Spray type | Continuous / Periodic |
| Temperature range | 35℃ to 55℃ |
| Temperature fluctuation | ≤±0.5℃ |
| Temperature uniformity | 2℃ |
| Humidity range | 95 to 98% RH |
| Spray type | Continuous / Periodic |
| Temperature range | 35℃ to 55℃ |
| Temperature fluctuation | ≤±0.5℃ |
| Temperature uniformity | 2℃ |
| Humidity range | 95 to 98 % RH |
| Volume | 300L |
| Temperature Range | Lights Off: 4°C to 50°C Light ON: 10°C to 50°C |
| Temperature Stability | ±1°C |
| Temperature Uniformity | ±2°C |
| Ambient Temperature | +5 ~ 30°C |