info@labozon.com +1 860 944 7786
Catalog from
Ion Chromatograph System LZ-ICS-A100
Catalog Original image

Ion Chromatograph System LZ-ICS-A100

www.labozon.com | info@labozon.com

Overview

Ion Chromatograph System LZ-ICS-A100 separates and quantifies ions in a liquid sample. Equipped with a high-performance chromatography pump, which has a maximum pressure of 35 MPa. It features an extensive flow range, spanning from 0.001 to 9.999 ml/min. This system is enhanced with low-pressure degassing technology. Our system is Incredibly reliable and presents effective performance.

Specifications :
Ion Chromatography Pump
Type High pressure and low pulse double plunger tandem advection pump
Maximum pressure 35 MPa (PEEK)
Display Pressure Accuracy ≤0.1 Mpa
Flow Stability (0.2 to 0.5) ml/ min ≤ 3 %,
(0.5 to 1.0) ml/ min ≤ 2 %,
> 1.0 ml/ min ≤ 2 %
Flow Range 0.001 to 9.999 ml/ min
Pressure Pulse ≤0.5 %
Numerical Control and Electromagnetic Injection
Maximum pressure 35 Mpa
Contact material of the rotor PEEK
Control mode By Stepper motor
Power supply DC 24 V
Column Heater
Operating temperature range Room temperature 20 to 60°C
Controlling temperature accuracy ± 0.01°C
Allowable deviation of column heater temperature ± 2°C
Temperature stability ≤1°C/ h
Flow System
Plastic Flow Path Made up of PEEK material
Six-Way Valve PEEK material pressure 5000 psi,
independent automatic collection, and flow function
Thermal Buffer System For Eluent
Temperature Range 25 to 40°C
Degassing Device
Type Built-in low pressure
Vacuum Degree -70 Kpa
Maximum Flow Rate 10ml/ min 90%
Internal Volume 30 µl
Degassing Efficiency 10ml/ min 90%
Digital Temperature And Control Detection System
Type Temperature-control and Bipolar conductivity detector
Detection Mode Bipolar conductivity detection
Cell Volume ≤ 0.8 µl
Detection Range 0 to 50000 µS/ cm
Output Voltage -6000 to +6000 mV (adjustable)
Operating Temperature Room temperature 5 to 60°C
Controlling Temperature Accuracy ± 0.01°C
Maximum Pressure 10 Mpa
Linear Range ≥ 103
Instrument Linearity ≥ 0.999
Quantitative Repeatability ≤ 1.0 %
Qualitative Repeatability ≤ 1.0 %
Eluent Generator
Eluent Type KOH/ NaOH
Eluent Concentration Range 0.1 to 100 mM
Concentration Increment 0.1 mM
Flow Rate Change 0.1 to 3.0 ml/ min
Maximum Pressure 20 Mpa
Minimum Pressure 5 Mpa
HS Code 9027201200
Power 150 W
Power Supply DC 220 V, 60 Hz
Dimension 500 × 500 × 760 mm
Net Weight 48 kg
Gross Weight 73 kg
Features :
  • Controlled by temperature, bipolar conductivity detector
  • Provides an advanced thermal buffer system for eluent
  • Equipped with an autosampler
  • Crafted with a PEEK material ion chromatographic pump
  • Facilitates the integration of One key step to finish the flow path switch
Optional Accessories :

Anion column


Guard column
Anion suppressor
UV detector
Ampere detector
Auto sampler (108) samples

Applications :

It is widely used in various scientific disciplines, including environmental analysis, pharmaceutical research, water quality monitoring, and industrial applications.

Catalog Footer logo

2025 © All Rights Reserved by Labozon.com