Liquid Chromatography-Mass Spectrometry LZ-LCMS-A100

Liquid Chromatography-Mass Spectrometry LZ-LCMS-A100 delivers ultra-trace detection for pharmaceutical, environmental, and food safety testing. Its triple quadrupole mass analyzer pairs with an automatic sample injector supporting up to 384 positions, backed by a column oven that holds six 250mm columns at once. Detection reaches 1pg on-column sensitivity with signal-to-noise above 100,000:1 — well suited for residue screening, drug metabolite profiling, and multi-compound quantitation in complex sample matrices.

Liquid Chromatography-Mass Spectrometry LZ-LCMS-A100 - Specifications

Gradient Pump Solvent Selection Two-solution selection (A/B or C/D) via automated selection valve.
Gradient Pump Degassing System Integrated vacuum degasser
Gradient Pump Flow Rate 1 to 4,000 µL/min.
Gradient Pump Maximum Operating Pressure ≥ 18,850 psi.
Gradient Pump Accuracy ≤ 1%.
Gradient Pump Precision ≤ 0.075% RSD.
Automatic Sample Injector Modes Full loop injection, partial loop injection, and microliter pickup.
Automatic Sample Injector Repeatability Full loop injection: < 0.3% RSD; Partial loop injection: < 0.3% RSD; Microliter pickup: < 1.0% RSD.
Automatic Sample Injector Cross-Contamination < 0.05%.
Column Oven Sample Capacity 384 positions (bits), and 96 positions (bits) for standard liquid injection.
Column Oven Temperature Control Range RT +5 °C to 90 °C.
Column Oven Temperature Control Mode Flowing phase preheating + forced air circulation.
Maximum Column Capacity Up-to six 250 mm chromatographic columns
Ion Source Design Orthogonal vertical spray
Ion Source Gas Supply Requirements 1 loop of nitrogen for atomizing (0–2 L/min); 2 loops of nitrogen for desolvation (0–15 L/min).
Blowback Gas Design High-temperature nitrogen blowback (0–5 L/min)
Interface Heating 110 °C
Ion Optics 4-stage differential vacuum design with multi-quadrupole transmission
Mass Analyzer Type Triple quadrupole mass analyzer.
MS-Quadrupole Material High-precision pure Molybdenum (Mo)
MS-Cell Collision Cell
Mass Resolution 0.4 to 2 amu (user-adjustable).
Mass Stability Better than 0.1 amu over 24 hours.
Mass Analyzer Scanning Speed ≥ 20,000 amu/s.
Mass Range m/z 5 - 1,000 amu.
Mass Analyzer Dynamic Range 6 orders of magnitude.
Mass Analyzer Sensitivity ESI+, MRM mode: 1pg reserpine on-column, S/N ≥ 100,000:1; ESI-, MRM mode: 1pg chloramphenicol on-column, S/N ≥ 100,000:1.
Scanning Functions Full scan, selected ion monitoring (SIM), product ion scan, precursor ion scan, neutral loss scan, multiple reaction monitoring (MRM), positive/negative ion switching scan, etc.
Detector Technology Multiplier technology
Detector Type Pulse-counting detector
Detector Polarity Switching Time ≤ 50 ms (Positive/negative polarity switching).
Vacuum System Composed of a mechanical pump and a turbo molecular pump with a differential pumping system
Power Supply Five sets of single-phase AC(220 ± 20) V, 10A, 50 Hz
Product Dimensions 1000×700 ×600mm
Packing Dimensions 1400×680×920mm
1570×970×1020mm
810×700×790mm
Gross Weight 430 kg

Liquid Chromatography-Mass Spectrometry LZ-LCMS-A100 - Key Features

Liquid Chromatography-Mass Spectrometry LZ-LCMS-A100 - Standard Accessories

Liquid Chromatography-Mass Spectrometry LZ-LCMS-A100 - Optional Accessories

Liquid Chromatography-Mass Spectrometry LZ-LCMS-A100 - Applications

Liquid Chromatography-Mass Spectrometry is used to evaluate drug pharmokinetics, detect inborn errors of metabolism, peptide identification, trace harmful pollutants, pesticides, toxins, and chemical contaminants.