info@labozon.com +1-579-300-7483

Organic Elemental Analysis


Automatic Azotometer LZ-AA-B104

Samples 4 samples/batch
Digital Digest Furnace Yes
Range 0.1 to 240 mgN (nitrogen content 0.02 to 95%)
Distillation Rate 3 to 7 min/ sample
Sample Quantity solid ≤5g/unit, liquid ≤15ml/unit

Automatic Azotometer LZ-AA-B108

Samples 8 samples/batch
Digital Digest Furnace Yes
Range 0.1 to 240 mgN (nitrogen content 0.02 to 95%)
Distillation Rate 3 to 7 min/ sample
Sample Quantity solid ≤5g/unit, liquid ≤15ml/unit

Automatic Azotometer LZ-AA-B112

Samples 12 samples/batch
Digital Digest Furnace Yes
Range 0.1 to 240 mgN (nitrogen content 0.02 to 95%)
Distillation Rate 3 to 7 min/ sample
Sample Quantity solid ≤5g/unit, liquid ≤15ml/unit

Automatic Azotometer LZ-AA-B120

Samples 20 samples/batch
Digital Digest Furnace Yes
Range 0.1 to 240 mgN (nitrogen content 0.02 to 95%)
Distillation Rate 3 to 7 min/ sample
Sample Quantity solid ≤5g/unit, liquid ≤15ml/unit

Automatic Kjeldahl Analyzer LZ-KA-A110

Measuring Range 0.1mg ~240mg N
Analysis time 5 – 10 min/ sample
Recovery ≥99.5%
Samples available Solid ≤ 5g; Liquid ≤20ml
Burette accurate 2.0μL/ step

Automatic Kjeldahl Analyzer LZ-KA-A111

Measuring Range 0.1mg ~240mg N
Analysis time 3 – 6 min/ sample
Recovery ≥99.5%
Samples available Solid ≤ 6g; Liquid ≤16ml
Cooling water consumption 1.5L/min

Semi-Automatic Kjeldahl Analyzer LZ-KA-A112

Measuring Range 0.1mg ~200mg N
Analysis time 5-15 min/ sample (depending on sample)
Recovery ≥99.9%
Repeatability ±1%
Samples Solid 0.20g ~2.00g
Semi-Fixed: 2.00g ~5.00g
Liquid: 10.00ml ~25.00 ml

Semi-Automatic Kjeldahl Analyzer LZ-KA-A113

Measuring Range 0.1mg ~240mg N
Analysis Speed 3-6min/Sample
Analysis Time 0~60min
Recovery ≥99.5%
Repeatability ≤0.5%

Graphite Digester LZ-GD-A100

Temperature range Room temperature +5 - 450℃
Temperature accuracy ±1℃
Heating method Infrared heating and high-purity graphite conduction
Heating insulation method Unique air duct insulation technology
Digestion tube capacity 300 ml

Graphite Digester LZ-GD-A101

Capacity 10 pcs
Temperature Range RT +5°C ~ 450°C
Temperature Accuracy +1°C
Digestion Tube Glass tube 300ml*10
Heating Mode Infrared heating and high purity graphite conductor

Carbon Sulphur Analyzer LZ-CSA-A100

Measurement Range
Carbon0.0001%-95.0000% (can be expanded to 99.9999
Sulfur0.0001%-95.0000% (can be expanded to 99.9999%)
Analysis Time Adjustable within 25-60 s (Normally around 35s)
Sensitivity 0.1 ppm
Working Gas Oxygen, Purity > 99.5%
Analysis Error Meets ISO9556 (Carbon), ISO4935 (Sulfur), JJG395-97 standards

Dumas Nitrogen Analyzer LZ-NDA-A100

Measure range 0.1~500 mg N
Sample injector 60 positions
Sample weight Solid≤1g
Liquid≤1ml
Analysis time 3-4minutes / piece
Recovery rate ≥99.5%

Exhaust System Scrubber LZ-ESS-A100

Extraction Flow 40 L/min
Air Extraction Interface Φ8~10mm(Reducer fittings are available)
Alkaline Solution 3 L PP bottle
Distilled Water 3 L PP bottle
Alkali Concentration 10%-35%
Enquiry form

2026 © All Rights Reserved by Labozon.com