info@labozon.com +1-579-300-7483

Semi-Automatic Kjeldahl Analyzer LZ-KA-A113

Semi-Automatic Kjeldahl Analyzer LZ-KA-A113 is designed for accurate determination of nitrogen and protein content using the classical Kjeldahl analysis method. Engineered for laboratory and quality control applications, the system provides reliable distillation and nitrogen measurement performance for food, agriculture, environmental, pharmaceutical, and chemical testing laboratories. Its semi-automatic design ensures stable analysis with precise reagent dosing and consistent recovery rates for dependable testing results. Equipped with a corrosion-resistant construction, digital control interface, and efficient steam generation system, supports routine nitrogen determination workflows with enhanced safety and repeatability. The compact benchtop design makes it suitable for continuous laboratory operation requiring protein and nitrogen analysis.

Semi-Automatic Kjeldahl Analyzer LZ-KA-A113 - Specifications

Measuring Range 0.1mg ~240mg N
Analysis Speed 3-6min/Sample
Analysis Time 0~60min
Recovery ≥99.5%
Repeatability ≤0.5%
Samples Solid≤6g; Liquid≤20mL
Cooling Water Consumption 1.5L/min
Operation Mode Automatic/manual dual modes
Display 7 inches LCD display
Reagent Bottles 4pcs
Power Consumption 1.4KW
Power Supply Standard:220V, 50/60Hz; Optional: 110V, 50/60Hz
External Dimensions 490 x 380 x 725mm
Packing Dimensions 630 x 560 x 1350mm
Net Weight 35 kg
Gross Weight 52kg

Semi-Automatic Kjeldahl Analyzer LZ-KA-A113 - Key Features

Semi-Automatic Kjeldahl Analyzer LZ-KA-A113 - Optional Accessories

Semi-Automatic Kjeldahl Analyzer LZ-KA-A113 - Applications

Used for nitrogen and protein determination in food products, dairy, feed, grain, fertilizers, soil, pharmaceuticals, chemicals, environmental samples, and agricultural testing laboratories.

Request a Quote

Automatic Azotometer

Fully Automatic Kjeldahl Analyzer

Graphic Digester

Carbon Sulphur Analyzer

Labozon Carbon Sulphur Analyzer fits lab schedules where combustion-based testing is a fixed step before results get logged. Samples load into ceramic crucibles, combustion and detection run in one pass, and carbon plus sulphur readings exit in 25 to 60 seconds, often closer to 35 seconds. Manufactured for labs where sample pace directly affects downstream output, this range keeps foundry and steel line testing moving without holds between batches.