info@labozon.com +1 (581) 875-5585

Organic Elemental Analysis


Automatic Azotometer LZ-AA-B104

Samples4 samples/batch
Digital Digest FurnaceYes
Range0.1 to 240 mgN (nitrogen content 0.02 to 95%)
Distillation Rate3 to 7 min/ sample
Sample Quantitysolid ≤5g/unit, liquid ≤15ml/unit

Automatic Azotometer LZ-AA-B108

Samples8 samples/batch
Digital Digest FurnaceYes
Range0.1 to 240 mgN (nitrogen content 0.02 to 95%)
Distillation Rate3 to 7 min/ sample
Sample Quantitysolid ≤5g/unit, liquid ≤15ml/unit

Automatic Azotometer LZ-AA-B112

Samples12 samples/batch
Digital Digest FurnaceYes
Range0.1 to 240 mgN (nitrogen content 0.02 to 95%)
Distillation Rate3 to 7 min/ sample
Sample Quantitysolid ≤5g/unit, liquid ≤15ml/unit

Automatic Azotometer LZ-AA-B120

Samples20 samples/batch
Digital Digest FurnaceYes
Range0.1 to 240 mgN (nitrogen content 0.02 to 95%)
Distillation Rate3 to 7 min/ sample
Sample Quantitysolid ≤5g/unit, liquid ≤15ml/unit

Automatic Kjeldahl Analyzer LZ-KA-A110

Measuring Range0.1mg ~240mg N
Analysis time5 – 10 min/ sample
Recovery≥99.5%
Samples availableSolid ≤ 5g; Liquid ≤20ml
Burette accurate2.0μL/ step

Automatic Kjeldahl Analyzer LZ-KA-A111

Measuring Range0.1mg ~240mg N
Analysis time3 – 6 min/ sample
Recovery≥99.5%
Samples availableSolid ≤ 6g; Liquid ≤16ml
Cooling water consumption1.5L/min

Semi-Automatic Kjeldahl Analyzer LZ-KA-A112

Measuring Range0.1mg ~200mg N
Analysis time5-15 min/ sample (depending on sample)
Recovery≥99.9%
Repeatability±1%
SamplesSolid 0.20g ~2.00g
Semi-Fixed: 2.00g ~5.00g
Liquid: 10.00ml ~25.00 ml

Semi-Automatic Kjeldahl Analyzer LZ-KA-A113

Measuring Range0.1mg ~240mg N
Analysis Speed3-6min/Sample
Analysis Time0~60min
Recovery≥99.5%
Repeatability≤0.5%

Graphite Digester LZ-GD-A100

Temperature rangeRoom temperature +5 - 450℃
Temperature accuracy±1℃
Heating methodInfrared heating and high-purity graphite conduction
Heating insulation methodUnique air duct insulation technology
Digestion tube capacity300 ml

Graphite Digester LZ-GD-A101

Capacity10 pcs
Temperature RangeRT +5°C ~ 450°C
Temperature Accuracy+1°C
Digestion TubeGlass tube 300ml*10
Heating ModeInfrared heating and high purity graphite conductor

Carbon Sulphur Analyzer LZ-CSA-A100

Measurement Range
Carbon0.0001%-95.0000% (can be expanded to 99.9999
Sulfur0.0001%-95.0000% (can be expanded to 99.9999%)
Analysis TimeAdjustable within 25-60 s (Normally around 35s)
Sensitivity0.1 ppm
Working GasOxygen, Purity > 99.5%
Analysis ErrorMeets ISO9556 (Carbon), ISO4935 (Sulfur), JJG395-97 standards

Dumas Nitrogen Analyzer LZ-NDA-A100

Measure range0.1~500 mg N
Sample injector60 positions
Sample weightSolid≤1g
Liquid≤1ml
Analysis time3-4minutes / piece
Recovery rate≥99.5%

Exhaust System Scrubber LZ-ESS-A100

Extraction Flow40 L/min
Air Extraction InterfaceΦ8~10mm(Reducer fittings are available)
Alkaline Solution3 L PP bottle
Distilled Water3 L PP bottle
Alkali Concentration10%-35%
Enquiry form

2026 © All Rights Reserved by Labozon.com