Chromatography


Gas Chromatography Mass Spectrometry LZ-GCMS-A879

Gas Chromatography Specifications
Flow rate1 ~ 1.5 ml / min
Maximum flow rate10 ml / min
Inlet temperature450 °C
Pressure range0 ~ 100 psi
Heating rateUp to 120 °C / min
Room temperature4 °C ~ 450 °C
Pressure control modeElectronic pressure control ( Supports CV and CC )
Split modeSplit / split less
Split ratio41.667361111111
Temperature programming7 stages / 8 platforms
Auto samplerOptional
Mass Spectrometry Specifications
Mass range1.5 ~ 1000 amu
Ion – source temperature100 °C ~ 350 °C
GC-MS interface temperature450 °C
Scan rateUp to 10000 amu/s
Stability± 0.10 amu / 48 hrs.
Filament emission current0 ~ 350 µA
EI source ionization energy5 eV ~ 250 eV
ResolutionUnit resolution
DetectorHigh energy dynode electron multiplier
SensitivityFull scan ( S / N is ≥ 30 : 1 )
VacuumTurbo molecular pump ( 67 L/s )

Gas Chromatography LZ-GC-A100

Sample Introduction system Sample injector and Evaporation chamber
Column Oven
Temperature rangeAmbient temperature +7℃ ~ 400℃ (in 1℃ increment)
Temperature accuracy± 0.02℃
Cooling period400℃ to 50℃ in 8-10 min at 25℃ ambient
Temperature setting0.1℃~40℃/min (in 1℃ increment)
Program ramps7 ramps in total (10 ramps available with control workstation)
Dimensions284 x 280 x 241 mm (Inside)
340 x 345 x 281 mm ( Outside)
Flame Ionization Detector (FID)
Detection Limit≤3×10-12g/s (C16)
Base test result≤3×10-12g/s (C16)
Drift≤6×10-13A/30min
Noise≤5×10-14A
Linearity range≥106
Thermal ConductivityDetector (TCD)
Sensitivity≥5000mV, mL/mg (C16)
Baseline noise≤20µV
Drift≤60µV/h
Linearity range≥104
Flame Photometric Detector(FPD)
Detection limit≤8×10-13g/s(P) ; ≤8×10-11g/s(S)
Drift≤2×10-11A/30min
Baseline noise≤5×10-12A

Ion Chromatograph System LZ-ICS-A100

Ion Chromatography Pump
TypeHigh pressure and low pulse double plunger tandem advection pump
Maximum pressure35 MPa (PEEK)
Display Pressure Accuracy≤0.1 Mpa
Flow Stability(0.2 to 0.5) ml/ min ≤ 3 %,
(0.5 to 1.0) ml/ min ≤ 2 %,
> 1.0 ml/ min ≤ 2 %
Flow Range0.001 to 9.999 ml/ min
Pressure Pulse≤0.5 %
Numerical Control and Electromagnetic Injection
Maximum pressure35 Mpa
Contact material of the rotorPEEK
Control modeBy Stepper motor
Power supplyDC 24 V
Column Heater
Operating temperature rangeRoom temperature 20 to 60°C
Controlling temperature accuracy± 0.01°C
Allowable deviation of column heater temperature± 2°C
Temperature stability≤1°C/ h
Flow System
Plastic Flow PathMade up of PEEK material
Six-Way ValvePEEK material pressure 5000 psi,
independent automatic collection, and flow function
Thermal Buffer System For Eluent
Temperature Range25 to 40°C