Tablet Hardness Tester
Dissolution Tester
Disintegration Tester
Friability Tester
Tap density Tester
Deblistering Machine
Microbial Limit Detector
Tablet Hardness Tester LZ-HDT-A100
| Hardness range | 2 to 199.9 N |
| Hardness accuracy | ± 1.5 % |
| Test period | 20 sec / pc |
| Safe testing force | 0.2 to 20 kg |
| Probe procession range | ≤ 20 mm |
Tablet Hardness Tester LZ-HDT-A101
| Hardness range | 2 to 199.9 N |
| Hardness accuracy | ± 1.5 % |
| Test period | 20 sec / pc |
| Safe testing force | 0.2 to 50 kg |
| Probe procession range | 3 to 40 mm |
Tablet Hardness Tester LZ-HDT-A102
| Hardness range | 2 to 199.9 N |
| Hardness accuracy | ± 1.5 % |
| Test period | 20 sec / pc |
| Safe testing force | 0.2 to 50 kg |
| Probe procession range | 3 to 40 mm |
Dissolution Tester LZ-DLT-A100
| No of vessels | 1 |
| No of poles | 1 |
| Position of vessels and poles | Arranged on one line |
| Speed range | 20 to 200 rpm |
| Speed accuracy | ± 2 rpm |
Dissolution Tester LZ-DLT-A101
| No of vessels | 3 |
| No of poles | 3 |
| Position of vessels and poles | Arranged on one line |
| Speed range | 20 to 200 rpm |
| Speed accuracy | ± 2 rpm |
Dissolution Tester LZ-DLT-A102
| No of vessels | 6 |
| No of poles | 6 |
| Position of vessels and poles | Arranged on one line |
| Speed range | 20 to 200 rpm |
| Speed accuracy | ± 2 rpm |
Dissolution Tester LZ-DLT-A103
| No of vessels | 6 |
| No of poles | 6 |
| Position of vessels and poles | Arranged on one line |
| Speed range | 20 to 200 rpm |
| Speed accuracy | ± 2 rpm |
Dissolution Tester LZ-DLT-A104
| No of vessels | 8 |
| No of poles | 6 |
| Position of vessels and poles | Six vessels and six poles in back and other two vessels at front |
| Speed range | 20 to 200 rpm |
| Speed accuracy | ± 2 rpm |
Dissolution Tester LZ-DLT-A105
| No of vessels | 8 |
| No of poles | 6 |
| Position of vessels and poles | Six vessels and six poles in back and other two vessels at front |
| Speed range | 20 to 200 rpm |
| Speed accuracy | ± 2 rpm |
Dissolution Tester LZ-DLT-A106
| No of vessels | 8 |
| No of poles | 8 |
| Position of vessels and poles | Four vessels and four poles in front and others at back |
| Speed range | 20 to 200 rpm |
| Speed accuracy | ± 2 rpm |
Dissolution Tester LZ-DLT-A107
| No. of vessels | 12 |
| No. of poles | 12 |
| Position of vessels and poles | Six vessels at the front and six vessels at the back |
| Speed range | 20 to 200 rpm |
| Speed accuracy | ± 2 rpm |
Disintegration Tester LZ-DGT-A100
| Basket assembly | 1 Piece |
| Quantity of Basket glass tube | 6 |
| Flat bottom beaker volume | 1000 ml |
| Nacelle back and forth frequency | 30 to 32 times / min |
| Nacelle back and forth range | 54 to 56 min |
Disintegration Tester LZ-DGT-A101
| Basket assembly | 2 Pieces |
| Quantity of Basket glass tube | 12 |
| Flat bottom beaker volume | 1000 ml |
| Nacelle back and forth frequency | 30 to 32 times / min |
| Nacelle back and forth range | 54 to 56 min |
Disintegration Tester LZ-DGT-A102
| Basket assembly | 3 Pieces |
| Quantity of Basket glass tube | 18 |
| Flat bottom beaker volume | 1000 ml |
| Nacelle back and forth frequency | 30 to 32 times / min |
| Nacelle back and forth range | 54 to 56 min |
Friability Tester LZ-FT-A100
| Cylinder Number | 2 |
| Cylinder Radius | Φ286 mm |
| Cylinder Depth | 39 mm |
| Tablet Fall Height | 156 mm |
| Rotation Speed Accuracy | ±1 rpm |
Friability Tester LZ-FT-A110
| Cylinder Number | 2 |
| Cylinder Radius | Φ286 mm |
| Cylinder Depth | 39 mm |
| Tablet Fall Height | 156 mm |
| Rotation Speed Accuracy | ±1 rpm |
Friability Tester LZ-FT-A120
| Cylinder Number | 2 |
| Cylinder Radius | Φ286 mm |
| Cylinder Depth | 39 mm |
| Tablet Fall Height | 156 mm |
| Rotation Speed Accuracy | ±1 rpm |
Tap Density Tester LZ-TDT-A100
| Number of Stations | 1 |
| Cylinder Volume | ≤ 250 ml |
| Sample Weight | ≤ 500 g |
| Number of Tap counts | 0 to 99999(set 0 to output bulk density) |
| Drop Height | 3 mm |
Tap density Tester LZ-TDT-A201
| Number of Stations | 2 |
| Cylinder Volume | ≤ 250 ml |
| Sample Weight | ≤ 500 g |
| Number of Tap counts | 0 to 99999(set 0 to output bulk density) |
| Drop Height | 3 mm |
Deblistering Machine LZ-DBM-A110
| Type | Automatic |
| Counting | Manual |
| Work efficiency | 50-65 plate/min |
| Scope of application | Capsules, tablets, soft capsules, candy, etc. All aluminum plastic packaging |
| Applicable medicine plate | Granules should be arranged horizontally and vertically |
Microbial Limit Detector LZ-MLD-A110
| Filter Cup | 100 ml |
| Flow Rate | ≥300ml/min (pump flow) |
| Vacuum | 60kpa |
| Filter | Trigeminy |
| Material | Stainless Steel |