info@labozon.com +1-579-300-7483

Water Testing Instrument


Multiparameter Portable Tester LZ-WQT-A100

Type Portable 
Display  Digital
pH
Range-2.00 to 20.00 pH 
Accuracy±0.002 pH 
Calibration Point1 to 5 ponit
Calibration SolutionUSA, NIST,DIN 
ORP
Range-1999.9 to1999.9 mV
Accuracy±0.2 mV
Calibration Point1 Point
Calibration SolutionmV & Relative mV
ION
Range0 to 19999 ppm, mg/l, mol/l, (depending on range of ISE)
Accuracy±0.5% F.S (Monovalent) ±1% F.S(Divalent)
Calibration Point2 to 5 point
Calibration Solution0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/l, mg/l

Multiparameter Benchtop Tester LZ-WQT-B100

Type Benchtop  
Display Digital
pH
Range-2.00 to 20.00 pH 
Accuracy±0.002 pH 
Calibration Point1 to 5 ponit
Calibration SolutionUSA, NIST,DIN 
ORP
Range-1999.9 to1999.9 mV
Accuracy±0.2 mV
Calibration Point1 Point
Calibration SolutionmV & Relative mV
ION
Range0 to 19999 ppm, mg/l, mol/l, (depending on range of ISE)
Accuracy±0.5% F.S (Monovalent) ±1% F.S(Divalent)
Calibration Point2 to 5 point
Calibration Solution0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/l

Benchtop PH Meter LZ-BPM-A100

pH Range -1.00 to 15.00 pH
pH Accuracy ± 0.01 pH
pH Resolution 0.01 pH
Calibration points 1-3 points
Calibration solutions USA (pH 4.0/7.00/10.01)

Benchtop PH Meter LZ-BPM-B100

pH Range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.01 pH/0.001
Calibration points 1-5 points
Calibration solutions USA

Portable PH Meter LZ-PPM-A500

pH Range (-2.00) to 16.00 Ph
pH Accuracy ± 0.01 pH
pH Resolution 0.01 pH
Calibration Points 2 points
Calibration Solutions USA (pH 4.01 / 7.00 / 10.01)

Portable PH Meter LZ-PPM-A510

pH Range -2.00 to 18.00 pH
pH Accuracy ±0.01 pH
pH Resolution 0.01 pH
Calibration 3 points
Auto Standard Recognition NIST buffers

Pocket Dissolved Oxygen Tester LZ-PDO-A102

Dissolved Oxygen Range 0.0 to 20.0 mg/L (or ppm)
Dissolved Oxygen Accuracy ± 0.5 mg/L
% of Saturation Of Oxygen 0.0 to 200.0%
Sensor Type Polarographic dissolved oxygen probe
% Saturation of Oxygen Accuracy ± 10 % F.S.

Benchtop Conductivity Meter LZ-BCM-A110

Conductivity Measurement Range 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity Accuracy ± 1 % F.S.
Conductivity Resolution 0.01, 0.1, 1
Conductivity Calibration Solutions 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Conductivity Calibration Points 1 - 3 points

Portable Conductivity Meter LZ-PCM-A110

Conductivity Range 0.00 μS/cm to 100 mS/cm
Conductivity Resolution 0.01 μS/cm
Conductivity Accuracy ±1.0% FS
Temperature 25 ºC
Reading Mode Continuous

Portable Conductivity Meter LZ-PCM-A111

Conductivity Range 0.00 μS/cm to 200 mS/cm
Conductivity Resolution 0.01 μS/cm minimum, various with range selection
Conductivity Accuracy ±1.0% FS
Conductivity Temperature 25 ºC
Calibration Points Up to 1

Water Hardness Electrode LZ-WHE-A100

Concentration Range 0.05 - 200 mmol/L
Slope 24 - 29 mV/decade
pH Range 2 ~ 11 pH
Temperature Range 5 ~50°C
Main Interferences Ba²⁺, Cd²⁺, Cu²⁺

BOD Meter LZ-BOD-A100

Range 0-4000 mg/L
Cycle length 1-30days
No. of samples ≤6
Culture bottle volume 580 ml
Data storage 10-year BOD 5 result value

COD Analyzer LZ-COD-A100

Measuring range (0 ~150)mg/L, (0 ~ 1500)mg/L
Accuracy ±8%
Repeatability 0.03
Fluctuation 6mg/L (20min)
Samples 21

COD Analyzer LZ-COD-A101

Test Method Fast digestion spectrophotometry
Detection Range 10 to 10000 mg/L
Accuracy 5%
Resolution 0.01
Light Source Imported Silicon Photodiode

Wall Mounted Chlorine Meter LZ-WCM-A100

HOCL Measuring Range 0 to 10.00 mg/L
Cl Measuring Range 0 to 20.00 mg/L
pH Range 0 to 14 pH
Temperature range 0 to 60°C
Resolution 0.001mg/L, 0.01mg/L, 0.01pH, 0.1°C

Water Activity Meter LZ-WTM-A100

Range 0 ~ 0.1 aw
Resolution 0.01 aw
Accuracy ±0.02 aw
Sensor Non conductive humidity sensor
Sampling Time 5mins

Turbidity Meter LZ-TBM-A100

Range 0 to 1100 NTU, 0 to 275 EBC, 0 to 9999 ASBC
Resolution 0.01 (0 to 99 NTU), 0.1 (100 to 999 NTU), 1 (1000 to 1100 NTU)
Accuracy ±2% (0 to 500 NTU), ±3% (501 to 1100 NTU)
Calibration Points 2 to 5 points
Calibration Standards 0.02, 10, 200, 500, 1000 NTU

Benchtop Water Hardness Meter LZ-BWM-A100

Measurement method Acidic cadmium lanthanum K photometric method
Measurement range 0.05~50mg/L
Repeatability ≤±5%
Error ≤8%
Stability ≤0.001A/10min
Enquiry form

2026 © All Rights Reserved by Labozon.com