Enquiry form
Advanced Gradient Thermal Cyclers LZ-GTC-A40
| Capacity | 96×0.2 ml |
| Tube | 0.2ml tube,8 strips, Half skirt96 wells plate, No skirt 96 wells plate |
| Temperature Range | 0 to 105 ℃ |
| Maximum Ramp Rate | 5 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Advanced Gradient Thermal Cyclers LZ-GTC-A41
| Capacity | 96×0.2 ml |
| Tube | 0.2ml tube,8 strips, Full 96 wells plate, Half skirt96 wells plate, No skirt 96 wells plate |
| Temperature Range | 0 to 105 ℃ |
| Maximum Ramp Rate | 6 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Advanced Gradient Thermal Cyclers LZ-GTC-A50
| Capacity | 6×16×0.2 ml |
| Tube | 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate |
| Temperature Range | 0 to 105 ℃ |
| Maximum Ramp Rate | 6 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Advanced Gradient Thermal Cyclers LZ-GTC-A51
| Capacity | 96×0.2 ml |
| Tube | 0.2ml tube, 8 strips, Half skirt96 wells plate, No skirt 96 wells plate |
| Temperature Range | 0 to 105 ℃ |
| Maximum Ramp Rate | 8 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Advanced Gradient Thermal Cyclers LZ-GTC-A60
| Capacity | 384 well |
| Tube | 384 PCR microplate |
| Temperature Range | 0 to 105 ℃ |
| Maximum Ramp Rate | 5 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Advanced Gradient Thermal Cyclers LZ-GTC-A70
| Capacity | 64×0.2ml (A Block) + 32×0.2ml (B Block) |
| Tube | 0.2 ml tube, 8 strips |
| Temperature Range | 0 to 105 ℃ |
| Maximum. Ramp Rate | 5 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Advanced Gradient Thermal Cyclers LZ-GTC-A71
| Capacity | 64×0.2ml (A Block) + 32×0.2ml (B Block) |
| Tube | 0.2 ml tube, 8 strips |
| Temperature Range | 0 to 105 ℃ |
| Maximum. Ramp Rate | 5 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Advanced Gradient Thermal Cyclers LZ-GTC-A80
| Capacity | 64×0.2 ml (A Block) + 32×0.2 ml (B Block) |
| Tube | 0.2 ml tube, 8 strips |
| Temperature Range | 0 to 105 ℃ |
| Maximum Ramp Rate | 8 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Automatic Gradient Thermal Cyclers LZ-GTC-B10
| Capacity | 96×0.2 ml |
| Test tube | 0.2ml single tube, 8 tubes, 96-well full skirt plate, 96-well half skirt plate, 96-well no skirt plate, |
| Temperature Range | 0 to 100 ℃ |
| Maximum Heating Rate | 5 ℃/s |
| Maximum Cooling Rate | 4 ℃/s |
Gradient Thermal Cycler LZ-GTC-A14
| Capacity | 96×0.2 ml |
| Temperature Range | 0 to 105 ℃ |
| Max. Ramp Rate | 5 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
| Accuracy | ≤ ± 0.1 ℃ |
Gradient Thermal Cycler LZ-GTC-A10
| Capacity | 96×0.2 ml |
| Temperature Range | 0 to 100℃ |
| Heating Rate | 4.5℃/s |
| Cooling Rate | 4℃/s |
| Uniformity | ≤±0.2℃ |
Gradient Thermal Cycler LZ-GTC-A11
| Capacity | 96×0.2ml+77×0.5 ml |
| Temperature Range | 0 to 100℃ |
| Heating Rate | 4.5℃/s |
| Cooling Rate | 4℃/s |
| Uniformity | ≤±0.2℃ |
Gradient Thermal Cycler LZ-GTC-A12
| Capacity | 60×0.5 ml |
| Temperature Range | 0 to 100℃ |
| Heating Rate | 4.5℃/s |
| Cooling Rate | 4℃/s |
| Uniformity | ≤±0.2℃ |
Gradient Thermal Cycler LZ-GTC-A13
| Capacity | 384 well |
| Temperature Range | 0 to 100℃ |
| Heating Rate | 4.5℃/s |
| Cooling Rate | 4℃/s |
| Uniformity | ≤±0.2℃ |
Gradient Thermal Cycler LZ-GTC-A30
| Capacity | 96×0.2 ml(6 independent 16 well block) |
| Temperature Range | 4 to 100 ℃ |
| Maximum Heating Rate | 6 ℃/s |
| Maximum Cooling Rate | 4 ℃/s |
| Uniformity | ≤ ± 0.3 ℃ |
Gradient thermal cycler LZ-GTC-A20
| Capacity | 96×0.2 ml |
| Temperature Range | 0 to 99.9 ℃ |
| Heating Rate | 4.5 ℃/s |
| Cooling Rate | 4 ℃/s |
| Uniformity | ≤ ± 0.3 ℃ |
Gradient thermal cycler LZ-GTC-A21
| Capacity | 96×0.2 ml+77×0.5 ml |
| Temperature Range | 0 to 99.9 ℃ |
| Heating Rate | 4.5 ℃/s |
| Cooling Rate | 4 ℃/s |
| Uniformity | ≤ ± 0.3 ℃ |
Gradient thermal cycler LZ-GTC-A22
| Capacity | 60×0.5ml |
| Temperature Range | 0 to 99.9 ℃ |
| Heating Rate | 4.5 ℃/s |
| Cooling Rate | 4 ℃/s |
| Uniformity | ≤ ± 0.3 ℃ |
Dual Block Thermal Cyclers LZ-DTC-D11
| Capacity | Double 48×0.2 ml |
| Temperature Range | 0 to 100 ℃ |
| Heating Rate | 5 ℃/s |
| Cooling Rate | 4 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Dual Block Thermal Cyclers LZ-DTC-D12
| Capacity | 48×0.2 ml+30×0.5 ml |
| Temperature Range | 0 to 100 ℃ |
| Heating Rate | 5 ℃/s |
| Cooling Rate | 4 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Dual Block Thermal Cyclers LZ-DTC-D13
| Capacity | 384well |
| Temperature Range | 0 to 100 ℃ |
| Heating Rate | 5 ℃/s |
| Cooling Rate | 4 ℃/s |
| Uniformity | ≤ ± 0.2 ℃ |
Trio Block Thermal Cyclers LZ-TTC-T10
| Capacity | 3×(32×0.2 ml ) |
| Temperature Range | 0 to 100℃ |
| Heating Rate | 5 ℃/s |
| Cooling Rate | 4 ℃/s |
| Uniformity | ≤ ± 0.3 ℃ |
Trio Block Thermal Cyclers LZ-TTC-T11
| Capacity | 3×(32×0.2 ml ) |
| Temperature Range | 0 to 100℃ |
| Heating Rate | 5 ℃/s |
| Cooling Rate | 4 ℃/s |
| Uniformity | ≤ ± 0.3 ℃ |
Q-Gene Thermal Cyclers LZ-TC-A10
| Capacity | 16×0.2 ml (4×4 layout) |
| Tube | 0.2 ml single tube |
| Temperature Range | 4 to 100 ℃ |
| Maximum Heating Rate | 5 ℃/s |
| Maximum Cooling Rate | 4 ℃/s |
Q-Gene Thermal Cyclers LZ-TC-A11
| Capacity | 32×0.2 ml (4×8 layout) |
| Tube | 0.2 ml single tube,8 strip |
| Temperature Range | 4 to 100 ℃ |
| Maximum Heating Rate | 5 ℃/s |
| Maximum Cooling Rate | 4 ℃/s |
Q-Lab Thermal Cyclers LZ-TC-A20
| Capacity | 120×80 mm |
| Temperature Range | 0 to 100℃ |
| Heating Rate | 4 ℃/s |
| Cooling Rate | 3 ℃/s |