Multiparameter Portable Tester LZ-WQT-A100
| Type | Portable | ||||||||
| Display | Digital | ||||||||
| pH |
|
||||||||
| ORP |
|
||||||||
| ION |
|
Multiparameter Benchtop Tester LZ-WQT-B100
| Type | Benchtop | ||||||||
| Display | Digital | ||||||||
| pH |
|
||||||||
| ORP |
|
||||||||
| ION |
|
Benchtop PH Meter LZ-BPM-A100
| pH Range | -1.00 to 15.00 pH |
| pH Accuracy | ± 0.01 pH |
| pH Resolution | 0.01 pH |
| Calibration points | 1-3 points |
| Calibration solutions | USA (pH 4.01/7.00/10.01), NIST (pH 4.01/6.86/9.18) |
Benchtop PH Meter LZ-BPM-B100
| pH Range | -2.00 to 20.00 pH |
| pH Accuracy | ± 0.002 pH |
| pH Resolution | 0.01 pH/0.001 |
| Calibration points | 1-5 points |
| Calibration solutions | USA |
Portable PH Meter LZ-PPM-A500
| pH Range | (-2.00) to 16.00 Ph |
| pH Accuracy | ± 0.01 pH |
| pH Resolution | 0.01 pH |
| Calibration Points | 2 points |
| Calibration Solutions | USA (pH 4.01 / 7.00 / 10.01) |
Portable PH Meter LZ-PPM-A510
| pH Range | -2.00 to 18.00 pH |
| pH Accuracy | ±0.01 pH |
| pH Resolution | 0.01 pH |
| Calibration | 3 points |
| Auto Standard Recognition | NIST buffers |
Pocket Dissolved Oxygen Tester LZ-PDO-A102
| Dissolved Oxygen Range | 0.0 to 20.0 mg/L (or ppm) |
| Dissolved Oxygen Accuracy | ± 0.5 mg/L |
| % of Saturation Of Oxygen | 0.0 to 200.0% |
| Sensor Type | Polarographic dissolved oxygen probe |
| % Saturation of Oxygen Accuracy | ± 10 % F.S. |
Benchtop Conductivity Meter LZ-BCM-A100
| Parameters | Conductivity, Resistivity, TDS, Salinity, Temp |
| Conductivity Range | 0.000μS/cm~1000mS/cm |
| Conductivity Accuracy | ±0.5%FS |
| Conductivity Resolution | 0.001 μ S/cm minimum, various with range selection |
| Reference Temperature | 20, 25ºC |
Benchtop Conductivity Meter LZ-BCM-A110
| Conductivity Measurement Range | 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm |
| Conductivity Accuracy | ± 1 % F.S. |
| Conductivity Resolution | 0.01, 0.1, 1 |
| Conductivity Calibration Solutions | 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm |
| Conductivity Calibration Points | 1 - 3 points |
Portable Conductivity Meter LZ-PCM-A110
| Conductivity Range | 0.00 μS/cm to 100 mS/cm |
| Conductivity Resolution | 0.01 μS/cm |
| Conductivity Accuracy | ±1.0% FS |
| Temperature | 25 ºC |
| Reading Mode | Continuous |
Portable Conductivity Meter LZ-PCM-A111
| Conductivity Range | 0.00 μS/cm to 200 mS/cm |
| Conductivity Resolution | 0.01 μS/cm minimum, various with range selection |
| Conductivity Accuracy | ±1.0% FS |
| Conductivity Temperature | 25 ºC |
| Calibration Points | Up to 1 |
Water Hardness Electrode LZ-WHE-A100
| Concentration Range | 0.05 - 200 mmol/L |
| Slope | 24 - 29 mV/decade |
| pH Range | 2 ~ 11 pH |
| Temperature Range | 5 ~50°C |
| Main Interferences | Ba²⁺, Cd²⁺, Cu²⁺ |
BOD Meter LZ-BOD-A100
| Range | 0-4000 mg/L |
| Cycle length | 1-30days |
| No. of samples | ≤6 |
| Culture bottle volume | 580 ml |
| Data storage | 10-year BOD 5 result value |
COD Analyzer LZ-COD-A100
| Measuring range | (0 ~150)mg/L, (0 ~ 1500)mg/L |
| Accuracy | ±8% |
| Repeatability | 0.03 |
| Fluctuation | 6mg/L (20min) |
| Samples | 21 |
COD Analyzer LZ-COD-A101
| Test Method | Fast digestion spectrophotometry |
| Detection Range | 10 to 10000 mg/L |
| Accuracy | 5% |
| Resolution | 0.01 |
| Light Source | Imported Silicon Photodiode |
Wall Mounted Chlorine Meter LZ-WCM-A100
| HOCL Measuring Range | 0 to 10.00 mg/L |
| Cl Measuring Range | 0 to 20.00 mg/L |
| pH Range | 0 to 14 pH |
| Temperature range | 0 to 60°C |
| Resolution | 0.001mg/L, 0.01mg/L, 0.01pH, 0.1°C |
Water Activity Meter LZ-WTM-A100
| Range | 0 ~ 0.1 aw |
| Resolution | 0.01 aw |
| Accuracy | ±0.02 aw |
| Sensor | Non conductive humidity sensor |
| Sampling Time | 5mins |
Turbidity Meter LZ-TBM-A100
| Range | 0 to 1100 NTU, 0 to 275 EBC, 0 to 9999 ASBC |
| Resolution | 0.01 (0 to 99 NTU), 0.1 (100 to 999 NTU), 1 (1000 to 1100 NTU) |
| Accuracy | ±2% (0 to 500 NTU), ±3% (501 to 1100 NTU) |
| Calibration Points | 2 to 5 points |
| Calibration Standards | 0.02, 10, 200, 500, 1000 NTU |
Benchtop Water Hardness Meter LZ-BWM-A100
| Measurement method | Acidic cadmium lanthanum K photometric method |
| Measurement range | 0.05~50mg/L |
| Repeatability | ≤±5% |
| Error | ≤8% |
| Stability | ≤0.001A/10min |
Pen-type PH Meter LZ-PHM-A100
| pH Measurement Range | 2.01 – 12.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range | 0–50°C (32–122°F) |
| Temperature Resolution | 0.1°C / 0.1°F |