Water Testing Instrument


Multiparameter Portable Tester LZ-WQT-A100

TypePortable 
Display Digital
pH
Range-2.00 to 20.00 pH 
Accuracy±0.002 pH 
Calibration Point1 to 5 ponit
Calibration SolutionUSA, NIST,DIN 
ORP (Optional)
Range+1999.9 mV
Accuracy±0.2 mV
Calibration Point1 Point
Calibration SolutionmV & Relative mV
ION (Optional)
Range0 to 19999 ppm, mg/l, mol/l, (depending on range of ISE)
Accuracy±0.5% F.S (Monovalent) ±1% F.S(Divalent)
Calibration Point2 to 5 point
Calibration Solution0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/l, mg/l

Multiparameter Benchtop Tester LZ-WQT-B100

TypeBenchtop  
DisplayDigital
pH
Range-2.00 to 20.00 pH 
Accuracy±0.002 pH 
Calibration Point1 to 5 ponit
Calibration SolutionUSA, NIST,DIN 
ORP
Range-1999.9 to1999.9 mV
Accuracy±0.2 mV
Calibration Point1 Point
Calibration SolutionmV & Relative mV
ION
Range0 to 19999 ppm, mg/l, mol/l, (depending on range of ISE)
Accuracy±0.5% F.S (Monovalent) ±1% F.S(Divalent)
Calibration Point2 to 5 point
Calibration Solution0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/l

Benchtop PH Meter LZ-BPM-A100

pH Range-1.00 to 15.00 pH
pH Accuracy± 0.01 pH
pH Resolution0.01 pH
Calibration points1-3 points
Calibration solutionsUSA (pH 4.01/7.00/10.01), NIST (pH 4.01/6.86/9.18)

Benchtop PH Meter LZ-BPM-B100

pH Range-2.00 to 20.00 pH
pH Accuracy± 0.002 pH
pH Resolution0.01 pH/0.001
Calibration points1-5 points
Calibration solutionsUSA

Portable PH Meter LZ-PPM-A500

pH Range(-2.00) to 16.00 Ph
pH Accuracy± 0.01 pH
pH Resolution0.01 pH
Calibration Points2 points
Calibration SolutionsUSA (pH 4.01 / 7.00 / 10.01)

Portable PH Meter LZ-PPM-A510

pH Range-2.00 to 18.00 pH
pH Accuracy±0.01 pH
pH Resolution0.01 pH
Calibration3 points
Auto Standard Recognition NIST buffers

Pocket Dissolved Oxygen Tester LZ-PDO-A102

Dissolved Oxygen Range0.0 to 20.0 mg/L (or ppm)
Dissolved Oxygen Accuracy± 0.5 mg/L
% of Saturation Of Oxygen0.0 to 200.0%
Sensor TypePolarographic dissolved oxygen probe
% Saturation of Oxygen Accuracy± 10 % F.S.

Benchtop Conductivity Meter LZ-BCM-A100

ParametersConductivity, Resistivity, TDS, Salinity, Temp
Conductivity Range0.000μS/cm~1000mS/cm
Conductivity Accuracy±0.5%FS
Conductivity Resolution0.001 μ S/cm minimum, various with range selection
Reference Temperature20, 25ºC

Benchtop Conductivity Meter LZ-BCM-A110

Conductivity Measurement Range0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity Accuracy± 1 % F.S.
Conductivity Resolution0.01, 0.1, 1
Conductivity Calibration Solutions10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Conductivity Calibration Points1 - 3 points

Portable Conductivity Meter LZ-PCM-A110

Conductivity Range 0.00 μS/cm to 100 mS/cm
Conductivity Resolution 0.01 μS/cm
Conductivity Accuracy ±1.0% FS
Temperature 25 ºC
Reading ModeContinuous

Portable Conductivity Meter LZ-PCM-A111

Conductivity Range 0.00 μS/cm to 200 mS/cm
Conductivity Resolution 0.01 μS/cm minimum, various with range selection
Conductivity Accuracy±1.0% FS
Conductivity Temperature 25 ºC
Calibration Points Up to 1

Water Hardness Electrode LZ-WHE-A100

Concentration Range0.05 - 200 mmol/L
Slope24 - 29 mV/decade
pH Range2 ~ 11 pH
Temperature Range5 ~50°C
Main InterferencesBa²⁺, Cd²⁺, Cu²⁺

BOD Meter LZ-BOD-A100

Range0-4000 mg/L
Cycle length1-30days
No. of samples≤6
Culture bottle volume580 ml
Data storage10-year BOD 5 result value

COD Analyzer LZ-COD-A100

Measuring range(0 ~150)mg/L, (0 ~ 1500)mg/L
Accuracy±8%
Repeatability0.03
Fluctuation6mg/L (20min)
Samples21

COD Analyzer LZ-COD-A101

Test MethodFast digestion spectrophotometry
Detection Range10 to 10000 mg/L
Accuracy5%
Resolution0.01
Light SourceImported Silicon Photodiode

Wall Mounted Chlorine Meter LZ-WCM-A100

HOCL Measuring Range0 to 10.00 mg/L
Cl Measuring Range0 to 20.00 mg/L
pH Range0 to 14 pH
Temperature range0 to 60°C
Resolution0.001mg/L, 0.01mg/L, 0.01pH, 0.1°C

Water Activity Meter LZ-WTM-A100

Range0 ~ 0.1 aw
Resolution0.01 aw
Accuracy±0.02 aw
SensorNon conductive humidity sensor
Sampling Time5mins

Turbidity Meter LZ-TBM-A100

Range0 to 1100 NTU, 0 to 275 EBC, 0 to 9999 ASBC
Resolution0.01 (0 to 99 NTU), 0.1 (100 to 999 NTU), 1 (1000 to 1100 NTU)
Accuracy±2% (0 to 500 NTU), ±3% (501 to 1100 NTU)
Calibration Points2 to 5 points
Calibration Standards0.02, 10, 200, 500, 1000 NTU

Benchtop Water Hardness Meter LZ-BWM-A100

Measurement methodAcidic cadmium lanthanum K photometric method
Measurement range0.05~50mg/L
Repeatability≤±5%
Error≤8%
Stability≤0.001A/10min

Pen-type PH Meter LZ-PHM-A100

pH Measurement Range2.01 – 12.00 pH
pH Resolution0.01 pH
pH Accuracy±0.02 pH
Temperature Range0–50°C (32–122°F)
Temperature Resolution0.1°C / 0.1°F

Portable Chlorine Meter LZ-PCL-A100

Test ParametersResidual Chlorine / Total Chlorine
Indication Error≤8%
Repeatability≤±3%
Optical Stability≤0.001 A / 10 min
Light Source Lifetime100,000 hours
Enquiry form

2026 © All Rights Reserved by Labozon.com