info@labozon.com +1-579-300-7483
Generate Catalog For:

Atomic Absorption Spectrophotometer LZ-AAS-A100 Catalog

Overview

Atomic Absorption Spectrophotometer LZ-AAS-A100 stands out as a rapid and efficient flame atomic absorption system. It incorporates Fast Sequential operation, accommodating up to 8 lamps, Hollow cathode lamps, and effective glass atomizers to enhance overall performance. With automatic lamp selection, a programmable gas box, and D2 background correction, the LZ-AAS-A100 offers advanced features. Additionally, it can be equipped with a diverse range of accessories to expand its functionalities. Well-suited for micronutrient analysis in applications such as environmental, food, and agriculture, this system effortlessly handles multi-element suites.

Specifications :
Wavelength Range 190 ~900 nm
Wavelength Accuracy ≤±0.15 nm
Wavelength Repeatability ≤0.4 nm
Bandwidth 0.1, 0.2, 0.4, 1.0, 2.0 nm
Baseline ≤0.002A/30mins (Cu)
Characteristic Concentration 0.02µg/ml/1% (Cu)
Detection Limit 0.004µg/ml (Cu)
Precision ≤0.5%
Grating Lines 1800/ mm
Inflamer All metal titanium burner
Atomizer Glass
Lamp 8
D2 Background Calibration 1 A ≤ 50 times correction ability
Flame System
Acetylene air burner100 mm
Ignition Dynamic Baseline Drift≤ 0.006 Abs / 30 min
Characteristic Concentration≤ 0.025 μg / ml / 1 %
Standard Deviation of Accuracy≤ 0.5 % (Cu, absorbance > 0.8 A) (detection limit Cu ≤ 0.008 μg / ml)
Safety SystemAutomatic cut off gas if pressure is low, power cut-off, flame out and alteration of the burner
Graphite Furnace (Optional)
Max.Temperature3000 ℃
Max. Heating Speed≥ 2000 ℃ / S
Characteristic quantity(Cd) ≤ 0.5 × 10 to 12g
(Cu) ≤ 0.5 × 10 to 11g
Accuracy(Cu) ≤3 % , (Cd) ≤ 3 %
Saftey SystemProtection for Overload current, reduced air pressure, low cooling water flow
Power Consumption7000W
Packing Dimensions760 x 640 x 700 mm
Weight90 kgs
Power Supply 220 V, 50 Hz
Overall Packing Dimensions 860 x 705 x 755 ( Main Instrument)
545 x 445 x 1385 (Accessories)
Gross Weight 105kgs ( Main Instrument)
100kgs ( Accessories)
Features :

  • Completely controlled by PC, simultaneous operation of flame and optional graphite furnace doubles your productivity
  • Design of an integrated floating optical platform enhances both the stability of the optical system and its resistance
  • Automate the switching of eight light stands while simultaneously pre-heating them, and optimizes the operational status of the hollow cathode lamp
  • Automatic adjustment ensures that the flame burner is positioned optimally
  • Fully automated wavelength scanning and peak searching
  • Alarm feature to protect gas leakage, wrong burner connection, low voltage, and abnormal flameout
  • D2 lamp protection and self- reversal background systems
  • Measuring method: Flame absorption method and emission method
  • Results can be printed in parameters, diagrams, data results
  • More than 500 self-storage data, analysed data is stored in Excel format
  • Each atomizer is aligned for immediate use and never needs re-alignment, enabling true set-and-forget optimization

Standard Accessories :

Software
Inkjet printer
Oil Free Air Compressor
Acetylene reducing valve
Cu Hollow Cathode Lamp
Air Filter

Optional Accessories :

Graphite Furnace
Hollow Cathode lamp( Ag, Au, Ca, Cd, Fr, Fe, Hg, K, Mg, Mn, Na,Ni, Pb, Zn, Sb etc)
Graphite Tubes
Recirculating cooling water system
Hydride Generator
Autosampler

Applications :

An atomic absorption spectrophotometer is used for quantitative analysis of metal elements and trace metals in environmental, food, pharmaceutical, clinical, and industrial samples.

logo