Atomic Absorption Spectrophotometer LZ-AAS-B100 Catalog | Labozon
info@labozon.com +1-579-300-7483
Generate Catalog For:

Atomic Absorption Spectrophotometer LZ-AAS-B100 Catalog

Overview

Atomic Absorption Spectrophotometer LZ-AAS-B100 stands out as a rapid and efficient flame atomic absorption system. It incorporates Fast Sequential operation, accommodating up to 8 lamps, Hollow cathode lamps, and effective glass atomizers to enhance overall performance. With automatic lamp selection, a programmable gas box, and D2 background correction, the LZ-AAS-A100 offers advanced features. Additionally, it can be equipped with a diverse range of accessories to expand its functionalities. Well-suited for micronutrient analysis in applications such as environmental, food, and agriculture, this system effortlessly handles multi-element suites.

Specifications :
Wavelength Range 190 ~900 nm
Wavelength Accuracy ≤±0.25 nm
Wavelength Repeatability ≤0.1 nm
Bandwidth 0.1, 0.2, 0.4, 0.7, 1.4 nm automatic switch
Baseline 0.004 Abs ( static state)
0.005 Abs (dynamic state)
Characteristic Concentration 0.025 µg/ml/1% (Cu)
Detection Limit 0.006 µg/ml (Cu)
Precision ≤1% (Cu)
Grating Lines 1800/ mm
Atomizer Flame
Lamp 8
D2 Background Calibration Ability to correct A1 background
Monochromator Czerny - Turner type
Power Supply 220 V, 50 Hz
Weight 180 kg
Features :

  • Completely controlled by PC, except for mainframe power switch
  • Design of an achromatic optical platform enhances both the stability of the optical system and its resistance
  • 8-element lamps, when one is working other seven are pre-heated at same time saving lamp exchange and pre heat time
  • USB 2.0mode with high communication speed
  • Ti atomization chamber, anti-erosion against acids and alkalis with longer working life
  • Glass nebulizer with better efficiency
  • C2H2 flow adjustable
  • Features safety measures gas leaking, air pressure monitoring, explosion, abnormal flameout
  • Fully automated wavelength scanning
  • D2 lamp protection and self- reversal background systems
  • Measuring method: Flame absorption method without background correction
  • Results can be printed in parameters, diagrams, data results

Standard Accessories :

Monochromator 
Photomultiplier tubes
Mass flow controller
Hollow cathode lamp
Burner head
Atomizing chamber
Efficient glass atomizer
Circuit control system

Optional Accessories :

Oil free air compressor
Autosampler
Hydride generator
Computer , printer

Applications :

An atomic absorption spectrophotometer is used for quantitative analysis of metal elements and trace metals in environmental, food, pharmaceutical, clinical, and industrial samples.

logo