Product Overview

Gradient thermal cycler LZ-GTC-A20

Gradient thermal cycler LZ-GTC-A20 enabled with Peltier heating units which can process more than 1000,000 cycles. It can accommodate 96×0.2 ml sample in wells. User-friendly programming is achieved via 5.7inch LCD with graphical display and windows operations system. This device can be applied across a temperature range of 0 to 99.9 ℃ with maximum ramping rate is 4.5 ℃/s.

MODELLZ-GTC-A20
EQUIPMENT TYPEGradient Thermal Cycler
Gradient thermal cycler LZ-GTC-A20

TECHNICAL DETAILS

SpecificationDetails
Product NameGradient thermal cycler LZ-GTC-A20
Model NumberLZ-GTC-A20
Capacity96×0.2 ml
Temperature Range0 to 99.9 ℃
Heating Rate4.5 ℃/s
Cooling Rate4 ℃/s
Uniformity≤ ± 0.3 ℃
Accuracy≤ ± 0.2 ℃
Display Resolution0.1 ℃
Temperature ControlBlock\Tube
Ramping Rate Adjustable0.1 to 4.5 ℃
Gradient Uniformity≤ ± 0.3 ℃
Gradient Accuracy≤ ± 0.2 ℃
Gradient Temperature Range30 to 99.9 ℃
Gradient Spread1 to 30℃
Hot Lid Temperature30 to 110℃
Hot Lid Height AdjustableStep less Adjustable
Number of Programs200
No.of Segment9
No.of Step9
No.of Cycle99
Increment/Decrement Time1 Second to 9 Min 59 Second
Temperature. Increment/Decrement0.1 to 9.9℃
Pause FunctionYes
Auto Data ProtectionYes
Graphical DisplayYes
Holding4 ℃
DisplayLCD
Power600 W
Voltage85 to 264 V AC , 50 to 60 Hz
Dimensions(L×W×H)392 mm×262 mm×252 mm (L×W×H)
Weight10 kg
LABOZON | LABORATORY SOLUTIONSPRODUCT CATALOG

Key Features

Uniform heating of the samples is achieved with Peltier heating units with more than 1,000,000 cycles

Maximum heating rate is 4.5 ℃/s with temperature range of 0 to 99.9 ℃

It has the capability to accommodate 96×0.2 ml, 96×0.2 ml+77×0.5 ml with moveable hot lid which can fit different sizes of tubes

All the operations are controlled by a computer software system which instrument PCR protocols

It has power of operation recovery option which helps in continuing the same command after a recovering from power cut

To satisfy the customers need it is installed with special feature like the user can add commands while the process is going on to encounter different variations

Applications

Used in Gene expression analysis
Pathogen detection
DNA methylation analysis
Genotyping and gene scanning
miRNA research etc.