info@labozon.com +1-579-300-7483

Atomic Absorption Spectrophotometer LZ-AAS-A100

Atomic Absorption Spectrophotometer LZ-AAS-A100 stands out as a rapid and efficient flame atomic absorption system. It incorporates Fast Sequential operation, accommodating up to 8 lamps, Hollow cathode lamps, and effective glass atomizers to enhance overall performance. With automatic lamp selection, a programmable gas box, and D2 background correction, the LZ-AAS-A100 offers advanced features. Additionally, it can be equipped with a diverse range of accessories to expand its functionalities. Well-suited for micronutrient analysis in applications such as environmental, food, and agriculture, this system effortlessly handles multi-element suites.

Atomic Absorption Spectrophotometer LZ-AAS-A100

Atomic Absorption Spectrophotometer LZ-AAS-A100 - Specifications

Wavelength Range 190 ~900 nm
Wavelength Accuracy ≤±0.15 nm
Wavelength Repeatability ≤0.4 nm
Bandwidth 0.1, 0.2, 0.4, 1.0, 2.0 nm
Baseline ≤0.002A/30mins (Cu)
Characteristic Concentration 0.02µg/ml/1% (Cu)
Detection Limit 0.004µg/ml (Cu)
Precision ≤0.5%
Grating Lines 1800/ mm
Inflamer All metal titanium burner
Atomizer Glass
Lamp 8
D2 Background Calibration 1 A ≤ 50 times correction ability
Flame System
Acetylene air burner100 mm
Ignition Dynamic Baseline Drift≤ 0.006 Abs / 30 min
Characteristic Concentration≤ 0.025 μg / ml / 1 %
Standard Deviation of Accuracy≤ 0.5 % (Cu, absorbance > 0.8 A) (detection limit Cu ≤ 0.008 μg / ml)
Safety SystemAutomatic cut off gas if pressure is low, power cut-off, flame out and alteration of the burner
Graphite Furnace (Optional)
Max.Temperature3000 ℃
Max. Heating Speed≥ 2000 ℃ / S
Characteristic quantity(Cd) ≤ 0.5 × 10 to 12g
(Cu) ≤ 0.5 × 10 to 11g
Accuracy(Cu) ≤3 % , (Cd) ≤ 3 %
Saftey SystemProtection for Overload current, reduced air pressure, low cooling water flow
Power Consumption7000W
Packing Dimensions760 x 640 x 700 mm
Weight90 kgs
Power Supply 220 V, 50 Hz
Overall Packing Dimensions 860 x 705 x 755 ( Main Instrument)
545 x 445 x 1385 (Accessories)
Gross Weight 105kgs ( Main Instrument)
100kgs ( Accessories)

Atomic Absorption Spectrophotometer LZ-AAS-A100 - Key Features

Atomic Absorption Spectrophotometer LZ-AAS-A100 - Standard Accessories

Software
Inkjet printer
Oil Free Air Compressor
Acetylene reducing valve
Cu Hollow Cathode Lamp
Air Filter

Atomic Absorption Spectrophotometer LZ-AAS-A100 - Optional Accessories

Graphite Furnace
Hollow Cathode lamp( Ag, Au, Ca, Cd, Fr, Fe, Hg, K, Mg, Mn, Na,Ni, Pb, Zn, Sb etc)
Graphite Tubes
Recirculating cooling water system
Hydride Generator
Autosampler

Atomic Absorption Spectrophotometer LZ-AAS-A100 - Applications

An atomic absorption spectrophotometer is used for quantitative analysis of metal elements and trace metals in environmental, food, pharmaceutical, clinical, and industrial samples.

Request a Quote

UV-VIS Spectrophotometers

NIR Spectrophotometer

Visible Spectrophotometer

Fluorescence Spectrophotometer

Portable Spectrophotometer

Nano Spectrophotometer