info@labozon.com +1 (581) 875-5585

Spectrophotometer


Single Beam UV-VIS Spectrophotometer LZ-UV-A110

Wavelength190 to 1100 nm
Wavelength SettingAuto
DisplayDigital
DetectorSilicon Photodiode
Accuracy±0.5 nm

Single Beam UV-VIS Spectrophotometer LZ-UV-A115

Wavelength190 to 1100 nm
Wavelength SettingAuto
Display320×240-inch LCD
DetectorSilicon Photodiode
Accuracy±0.5 nm

Single Beam UV-VIS Spectrophotometer LZ-UV-A120

Wavelength190 to 1100 nm
Wavelength SettingAuto
Display320×240-inch LCD
DetectorSilicon Photodiode
Accuracy±0.3 nm

Single Beam UV-VIS Spectrophotometer LZ-UV-A130

Wavelength190 to 1100 nm
Wavelength SettingAuto
Display320×240-inch LCD
DetectorSilicon Photodiode
Accuracy±0.3 nm

Single Beam UV-VIS Spectrophotometer LZ-UV-A135

Wavelength190 to 1100 nm
Wavelength SettingAuto
Display320×240-inch LCD
DetectorSilicon Photodiode
Accuracy±0.3 nm

Single Beam UV-VIS Spectrophotometer LZ-UV-A140

Wavelength Range190 to 1000 nm
Wavelength SettingAuto
Optical SystemSingle beam
Spectral Bandwidth2 nm
Wavlength Accuracy±1 nm

Single Beam UV-VIS Spectrophotometer LZ-UV-A145

Wavelength Range190 to 1100 nm
Wavelength SettingAuto
Optical SystemSingle beam
Spectral Bandwidth1.8 nm
Wavlength Accuracy± 0.5 nm

Single Beam UV-VIS Spectrophotometer LZ-UV-A150

Optical systemSingle Beam
Wavelength range190-1100 nm
Wavelength accuracy±0.5nm
Wavelength repeatability≤0.2nm
Bandwidth1.8 nm

Double Beam UV-VIS Spectrophotometers LZ-UV-B110 (Split Beam)

Photometry TypeSplit Beam
Wavelength190 to 1100 nm
Wavelength Accuracy± 0.5 nm
Wavelength Repeatability≤ 0.2 nm
Focal Length160 mm

Double Beam UV-VIS Spectrophotometer LZ-UV-B210

Wavelength190 to 1100 nm
DisplayDigital
DetectorSilicon Photodiode
Accuracy±0.3nm
Reproducibility0.2nm

Double Beam UV-VIS Spectrophotometer LZ-UV-B220

Wavelength190 to 1100 nm
DisplayDigital
DetectorSilicon Photodiode
Accuracy±0.3nm
Reproducibility0.2nm

Double Beam UV-VIS Spectrophotometer LZ-UV-B230

Wavelength190 to 1100 nm
DisplayDigital
DetectorDual detector
Accuracy±0.3nm
Reproducibility0.2nm

Double Beam UV-VIS Spectrophotometer LZ-UV-B240

Wavelength190 to 1100 nm
DisplayDigital
DetectorSilicon Photodiode
Accuracy±0.3nm
Reproducibility0.2nm

Double Beam UV-VIS Spectrophotometer LZ-UV-B250

Wavelength Range190-900 nm
DisplayDigital
Optical SystemDouble Beam
Spectral Bandwidth0.1~5.0 nm (0.1 nm interval continously adjustable
Wavelength Accuracy±0.3nm

Double Beam UV-VIS Spectrophotometer LZ-UV-B260

Wavelength190 to 1100 nm
DisplayTouch screen
DetectorDual detector
Accuracy±0.1nm(D2 656.1nm),±0.3 nm full range
Repeatability≤0.1nm

Double Beam UV-VIS Spectrophotometer LZ-UV-B270

Optical systemDouble Beam
Wavelength range190-1100 nm
Wavelength accuracy ±0. 1nm at D2 656.1nm, ±0.3nm at full range
Wavelength repeatability ≤0. 1nm
Bandwidth1 nm

Double Beam UV-VIS Spectrophotometer LZ-UV-B280

Optical systemDouble Beam
Wavelength range190-1100 nm
Wavelength accuracy±0. 1nm at D2 656.1nm, ±0.3nm at full range
Wavelength repeatability≤0. 1nm
Bandwidth1.8nm

NIR Spectrophotometer LZ-NIR-A100

Wavelength range900 nm to 2500 nm
Wavelength accuracy≤ 0.2
Wavelength Reproducibility≤ 0.05
Bandwidth8 nm
Measurement ModeTransmission

Visible Spectrophotometer LZ-VS-A100

Wavelength320 to 1100 nm
Wavelength SettingAutomatic
DisplayLCD display
DetectorSilicon Photodiode
Wavelength Accuracy±0.5nm

Fluorescence Spectrophotometer LZ-FS-A100

Wavelength200 to 650 nm
Bandwidth10 nm
Accuracy±1nm
Reproducibility≤0.5 nm
S/N ratioS/N ≥90

Fluorescence Spectrophotometer LZ-FS-A101

Optical SystemMonochromatic design
Measuring Wavelength200-900 nm ((on both EX and EM)
Spectral BandwidthExcitation Slit: 2nm、5nm、10nm、20nm
Emission Slit: 2nm、5nm、10nm、20nm
Wavelength Accuracy±1.0nm
Wavelength Repeatability0.5 nm

Fluorescence Spectrophotometer LZ-FS-A110

Excitation Source150 W Xenon Lamp
Excitation Wavelength200 nm to 900 nm
Excitation Slit1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Emission Slit1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Wavelength Accuracy± 0.4 nm

Atomic Absorption Spectrophotometer LZ-AAS-A100

Wavelength Range190 ~900 nm
Wavelength Accuracy≤±0.15 nm
Wavelength Repeatability≤0.4 nm
Bandwidth0.1, 0.2, 0.4, 1.0, 2.0 nm
Baseline≤0.002A/30mins (Cu)

Atomic Absorption Spectrophotometer LZ-AAS-B100

Wavelength Range190 ~900 nm
Wavelength Accuracy≤±0.25 nm
Wavelength Repeatability≤0.1 nm
Bandwidth0.1, 0.2, 0.4, 0.7, 1.4 nm automatic switch
Baseline0.004 Abs ( static state)
0.005 Abs (dynamic state)

Atomic Absorption Spectrophotometer LZ-AAS-B101

MonochromatorCzerny-Turner
Wavelength Coverage190–900 nm
Wavelength Accuracy±0.25 nm
Wavelength Repeatability<0.10 nm
Spectral BandwidthAutomatic switching: 0.1 / 0.2 / 0.4 / 0.7 / 1.4 nm

Portable Spectrophotometer LZ-SP-A100

TypePortable
Wavelength Range400-700 nm
Wavelength Interval10 nm
Reflectance Range0-200%
Reflectance Resolution0.0001

Nano Spectrophotometer LZ-NS-B100

Wavelength range190-1100 nm
Wavelength accuracy±1nm
Spectral resolution0.3 nm
DetectorCCD
LightXenon lamp

UV-Vis-NIR Spectrophotometer LZ-UVN-A100

Optical SystemDouble Beam
Wavelength Range190-3200 (Transmission and specular reflectance model
250-2500nm (Integrating Sphere mode)
Wavelength Accuracy±0.5nm (UV/VIS) ±0.4nm (NIR)
Wavelength Repeatability≤0.2nm (UV/VIS) ≤1nm (NIR)
Photometric Range0-3A

Benchtop Spectrophotometer LZ-BS-A100

Optical GeometryReflect: D/8 (diffused illumination, 8-degree viewing angle)
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source
Transmittance: D/0 (diffuse illumination: 0° viewing)
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source
HAZE (ASTM D1003)
Integrating SphereØ154 mm
Light Source360–780 nm combined LED with UV, 400/420/460 nm cut-off light source
Spectral MethodConcave grating
Sensor256-pixel dual-array CMOS image sensor
Enquiry form

2026 © All Rights Reserved by Labozon.com