info@labozon.com +1 860 944 7786

Spectrophotometer

Atomic Absorption Spectrophotometer

Fluorescence Spectrophotometer

NIR Spectrophotometer

Portable Spectrophotometer

UV-VIS Spectrophotometers

Visible Spectrophotometer

Atomic Absorption Spectrophotometer LZ-AAS-A100

  • Wavelength Range: 190 ~900 nm
  • Wavelength Accuracy: ≤±0.15 nm
  • Wavelength Repeatability: ≤0.4 nm
  • Bandwidth: 0.1, 0.2, 0.4, 1.0, 2.0 nm
  • Baseline: ≤0.002A/30mins (Cu)

Atomic Absorption Spectrophotometer LZ-AAS-B100

  • Wavelength Range: 190 ~900 nm
  • Wavelength Accuracy: ≤±0.25 nm
  • Wavelength Repeatability: ≤0.1 nm
  • Bandwidth: 0.1, 0.2, 0.4, 0.7, 1.4 nm automatic switch
  • Baseline: 0.004 Abs ( static state)<br/> 0.005 Abs (dynamic state)

Double Beam UV-VIS Spectrophotometer LZ-UV-B210

  • Wavelength: 190 to 1100 nm
  • Display: Digital
  • Detector: Silicon Photodiode
  • Accuracy: ±0.3nm
  • Reproducibility: 0.2nm
Double Beam UV-VIS Spectrophotometer LZ-UV-B220
  • Wavelength: 190 to 1100 nm
  • Display: Digital
  • Detector: Silicon Photodiode
  • Accuracy: ±0.3nm
  • Reproducibility: 0.2nm
Double Beam UV-VIS Spectrophotometer LZ-UV-B230
  • Wavelength: 190 to 1100 nm
  • Display: Digital
  • Detector: Dual detector
  • Accuracy: ±0.3nm
  • Reproducibility: 0.2nm

Double Beam UV-VIS Spectrophotometer LZ-UV-B240

  • Wavelength: 190 to 1100 nm
  • Display: Digital
  • Detector: Silicon Photodiode
  • Accuracy: ±0.3nm
  • Reproducibility: 0.2nm

Double Beam UV-VIS Spectrophotometer LZ-UV-B250

  • Wavelength Range: 190-900 nm
  • Display: Digital
  • Optical System: Double Beam
  • Spectral Bandwidth: 0.1~5.0 nm (0.1 nm interval continously adjustable
  • Wavelength Accuracy: ±0.3nm

Double Beam UV-VIS Spectrophotometer LZ-UV-B260

  • Wavelength: 190 to 1100 nm
  • Display: Touch screen
  • Detector: Dual detector
  • Accuracy: ±0.1nm(D2 656.1nm),±0.3 nm full range
  • Repeatability: ≤0.1nm
Double Beam UV-VIS Spectrophotometers LZ-UV-B110
  • Wavelength: 190 to 1100 nm
  • Display: 8-inch color touch screen
  • Accuracy: ± 0.5 nm
  • Reproducibility: ≤ 0.2 nm
  • Focal Length: 160 mm
Fluorescence Spectrophotometer LZ-FS-A100
  • Wavelength: 200 to 650 nm
  • Bandwidth: 10 nm
  • Accuracy: ±1nm
  • Reproducibility: ≤0.5 nm
  • S/N ratio: S/N ≥90

NIR Spectrophotometer LZ-NIR-A100

  • Wavelength range: 900 nm to 2500 nm
  • Wavelength accuracy: ≤ 0.2
  • Wavelength Reproducibility: ≤ 0.05
  • Bandwidth: 8 nm
  • Measurement Mode: Transmission

Portable Spectrophotometer LZ-SP-A100

  • Type: Portable
  • Wavelength Range: 400-700 nm
  • Wavelength Interval: 10 nm
  • Reflectance Range: 0-200%
  • Reflectance Resolution: 0.0001

Single Beam UV-VIS Spectrophotometer LZ-UV-A105

  • Wavelength: 190 to 1100 nm
  • Wavelength Setting: Auto
  • Display: Digital
  • Detector: Silicon Photodiode
  • Accuracy: ±0.8 nm
Single Beam UV-VIS Spectrophotometer LZ-UV-A110
  • Wavelength: 190 to 1100 nm
  • Wavelength Setting: Auto
  • Display: Digital
  • Detector: Silicon Photodiode
  • Accuracy: ±0.5 nm
Single Beam UV-VIS Spectrophotometer LZ-UV-A115
  • Wavelength: 190 to 1100 nm
  • Wavelength Setting: Auto
  • Display: 320×240-inch LCD
  • Detector: Silicon Photodiode
  • Accuracy: ±0.5 nm

Single Beam UV-VIS Spectrophotometer LZ-UV-A120

  • Wavelength: 190 to 1100 nm
  • Wavelength Setting: Auto
  • Display: 320×240-inch LCD
  • Detector: Silicon Photodiode
  • Accuracy: ±0.3 nm

Single Beam UV-VIS Spectrophotometer LZ-UV-A130

  • Wavelength: 190 to 1100 nm
  • Wavelength Setting: Auto
  • Display: 320×240-inch LCD
  • Detector: Silicon Photodiode
  • Accuracy: ±0.3 nm

Single Beam UV-VIS Spectrophotometer LZ-UV-A135

  • Wavelength: 190 to 1100 nm
  • Wavelength Setting: Auto
  • Display: 320×240-inch LCD
  • Detector: Silicon Photodiode
  • Accuracy: ±0.3 nm
Single Beam UV-VIS Spectrophotometer LZ-UV-A140
  • Wavelength Range: 190 to 1000 nm
  • Wavelength Setting: Auto
  • Optical System: Single beam
  • Spectral Bandwidth: 2 nm
  • Wavlength Accuracy: ±1 nm
Single Beam UV-VIS Spectrophotometer LZ-UV-A145
  • Wavelength Range: 190 to 1100 nm
  • Wavelength Setting: Auto
  • Optical System: Single beam
  • Spectral Bandwidth: 1.8 nm
  • Wavlength Accuracy: ± 0.5 nm

Visible Spectrophotometer LZ-VS-A100

  • Wavelength: 320 to 1100 nm
  • Wavelength Setting: Automatic
  • Display: LCD display
  • Detector: Silicon Photodiode
  • Wavelength Accuracy: ±0.5nm
Enquiry form

2025 © All Rights Reserved by Labozon.com