Automated Elisa Processor LZ-AEP-A100

Automated Elisa Processor LZ-AEP-A100

Operating Temperature10~30 ˚C Operating Humidity30%~ 80% Sample HandlingSamples: 192 samples (Extended up to 384); Pipette capacity: 10 to 1000µl; Dispensing: one aspirating and dispensing probe Reagent HandlingReagent racks: Universal- standard 6 positions (extended up to 32); Reagent bottle: Standard 20 reagent bottles position; Pipette capacity: 10 to 1000 µl; Pipette precision: (100 µl) CV≤0.5%; Time of Dispensing: 5mins (96 well microplates)

Automated Tissue Processor LZ-ATP-A100

Automated Tissue Processor LZ-ATP-A100

Capacity1100 ml per cup Number of cups12pcs ( 9pcs reagent cup, 3pcs paraffin cup) Cup processing time0-24 h Tissue protective cup7th Cup

Automated Tissue Stainer LZ-ATS-A100

Automated Tissue Stainer LZ-ATS-A100

Capacity1200 ml per cup Number of cups14pcs (1st is drying cup, 8th is washing cup) Cup processing time0-59min Slides Capacity72 pcs

Automated Tissue Processor LZ-ATP-B100

Automated Tissue Processor LZ-ATP-B100

TypeEnclosed type tissue processor Paraffin Wax TankNumber of tanks: 3; Volume: 4.0 L per tank; Melting time: approx. 3 hrs Processing Capacity100/200/300 Cassettes Temperature range65°C ( Paraffin); 35°C (Reagents)

Automated Tissue Processor LZ-ATP-B101

Automated Tissue Processor LZ-ATP-B101

Capacity≥5.5 L Sample Capacity≥600 tissue samples per cycle Wax Tank Capacity≥4.5 L each (multiple tanks) Magnetic stirring rotors2

Automated Tissue Processor LZ-ATP-A101

Automated Tissue Processor LZ-ATP-A101

Number of Liquid Cylinders12 (including 3 wax cylinders) Single Cylinder Volume2200 ml Basket CapacityHolds up to 125 specimens Single Cylinder Working timeAdjustable from 0-24hrs

Automated Immunohistochemistry Stainer LZ-IHS-A100

Automated Immunohistochemistry Stainer LZ-IHS-A100

Slides Capacity48 Reagents Capacity64 Minimum dropping reagent50µl Dropping reagent increment50ul, 100ul, 150ul, 200ul

Automated Blood Culture System LZ-ABC-A110

Automated Blood Culture System LZ-ABC-A110

Detection MethodColorimetric Sample TypeBlood and sterile body fluid specimens Capacity128 culture bottles Temperature ControllerCirculating air bath with precise temperature regulation

Automated Tissue Processor LZ-ATP-A102

Automated Tissue Processor LZ-ATP-A102

Processing Stations12 (including 3 paraffin stations) Station Volume1500ml Specimen Capacity per Basket96 specimens Station Dwell Time0–99 hours

Automated Tissue Processor LZ-ATP-A103

Automated Tissue Processor LZ-ATP-A103

Processing Stations12 (including 3 paraffin stations) Station Volume1000ml Specimen Capacity per Basket52 specimens Station Dwell Time0–99 hours

5 Parts Hematology Analyzer LZ-HTA-A100

5 Parts Hematology Analyzer LZ-HTA-A100

Measuring principleTri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test Sample volumesCBC+DIFF mode: ≤ 20 μl CBC mode: ≤ 10 μl Throughput60 tests/hour Assay Items5 parts, 29 parameters, 3 histograms and 3D scattergrams

3 Parts Hematology Analyzer LZ-HTA-B100 (VET)

3 Parts Hematology Analyzer LZ-HTA-B100 (VET)

Measuring principleElectrical resistance for counting; hemiglobincyanide and SFT method for hemoglobin Animal TypeDog, Cat, Horse, Mouse, Rat, Rabbit, Pig, Cow, Monkey, Sheep and 5 user defined animals Sample Volumes9.8μL Venous and capillary; 20μL pre-diluted Throughput35 samples / hr

5 Parts Hematology Analyzer LZ-HTA-A101 (VET)

5 Parts Hematology Analyzer LZ-HTA-A101 (VET)

Measuring principleTri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test Sample VolumesCBC+DIFF mode: ≤ 20 μl; CBC mode: ≤ 10 μl Throughput60 tests/hour Assay Items5 parts, 25 parameters, 3 histograms and 3D scattergrams

3 Parts Hematology Analyzer LZ-HTA-B110

3 Parts Hematology Analyzer LZ-HTA-B110

Measuring principleElectrical resistance for counting; SFT method for hemoglobin Sample Volumes9.6μL Venous and capillary; 20μL pre-diluted; 9.6μL capillary Throughput40 samples / hour Assay Items3 parts, 20 parameters and 3 color histograms

5 Parts Hematology Analyzer LZ-HTA-A102

5 Parts Hematology Analyzer LZ-HTA-A102

Measuring PrincipleSheath flow impedance and multi-angle laser scattering SampleVenous, capillary, pre-diluted Sample VolumeCBC 20 µl; CBC+DIFF20 µl; pre-dilution mode 20µl AccuracyWBC CV≤2.0% (3.5~15.00×109/L); RBC CV≤1.5% (3.50~6.00×1012/L); HGB CV≤1.5% (110~180g/L); PLT CV≤6.0% (100~149×109/L); CV≤4.0% (150~500×109/L)

Auto Chemistry Analyzer LZ-ACA-A100

Auto Chemistry Analyzer LZ-ACA-A100

Wavelength340,405,450,510,546,578,630,700nm Sample Volume2-70 µl Reagent Volume20-350 µl Sample Positions49 sample positions

Electrolyte Analyzer LZ-EA-A100

Electrolyte Analyzer LZ-EA-A100

Measured ElectrolytesK⁺, Na⁺, Cl⁻ Detection TechnologyIon selective electrode (ISE) Sample Volume60~150μl Test Time≤25s

Halogen Moisture Analyzer LZ-HMA-A100

Halogen Moisture Analyzer LZ-HMA-A100

Capacity10 mg to 110 g Readability10 mg Temperature range40 to 199˚C SensorLoad cell

Halogen Moisture Analyzer LZ-HMA-A101

Halogen Moisture Analyzer LZ-HMA-A101

Capacity5 mg to 110 g Readability5 mg Temperature range40 to 199˚C SensorLoad cell

Halogen Moisture Analyzer LZ-HMA-A102

Halogen Moisture Analyzer LZ-HMA-A102

Capacity2 mg to 110 g Readability2 mg Temperature range40 to 199˚C SensorLoad cell

Halogen Moisture Analyzer LZ-HMA-A103

Halogen Moisture Analyzer LZ-HMA-A103

Capacity1 mg to 110 g Readability1 mg Temperature range40 to 199˚C SensorLoad cell

Semi Auto- Chemistry Analyzer LZ-SCA-A100

Semi Auto- Chemistry Analyzer LZ-SCA-A100

Wavelength340,405,450,510,546,578,630 nm Wavelength Accuracy±2nm Measuring range0 to 3.500 OD Incubating Positions20

COD Analyzer                   LZ-COD-A100

COD Analyzer LZ-COD-A100

Measuring range(0 ~150)mg/L, (0 ~ 1500)mg/L Accuracy±8% Repeatability0.03 Fluctuation6mg/L (20min)

Automatic Biochemistry Analyzer LZ-BCA-A100

Automatic Biochemistry Analyzer LZ-BCA-A100

Sample Volume1 to 100 µl; 0.1 µl/step Reagent position40 or 80 (optional) Reagent volume R11 to 400 µl, 1 µl / step Reagent volume R21 to 400 µl, 1 µl / step

Auto Chemistry Analyzer LZ-ACA-A101

Auto Chemistry Analyzer LZ-ACA-A101

Throughput400 tests/hour Sample Volume2 to 70 µl Reagent Volume20 to 350 µl Sample Positions60/90

Fiber Analyzer LZ-FBA-A100

Fiber Analyzer LZ-FBA-A100

Operation ModeManual or Automatic Capacity6 pcs / batch Sample Weighing0.5 ~ 3.0 g Test Range0 - 100 %

Automatic (Soxhlet) Fat Analyzer LZ-SFA-A100

Automatic (Soxhlet) Fat Analyzer LZ-SFA-A100

Capacity per batch6pcs / batch Sample Weight0.5-15 g Solvent cup volume150 ml Solvent recovery>85%

Auto Chemistry Analyzer LZ-ACA-A102

Auto Chemistry Analyzer LZ-ACA-A102

Throughput300 tests/ hour Sample Volume2 to 30 µl; 0.1µl increment Reagent Volume20-300µl; 0.1µl increment Sample Positions120

Urine Analyzer LZ-UA-A100

Urine Analyzer LZ-UA-A100

Testing ItemsGLU,BIL,KET,SG,pH,BLD, PRO,URO,NIT,LEU,VC,CRE,CAL,MAL Test Speed514 Tests/ hour Display7 inch touch screen Temperature Range15 ~35°C

Semi Auto- Chemistry Analyzer LZ-SCA-A110

Semi Auto- Chemistry Analyzer LZ-SCA-A110

Wavelength340,405,492,510,546,578,630 nm Wavelength Accuracy±2nm Measuring range450 µl -800 µl Incubating Positions20

Automatic Kjeldahl Analyzer LZ-KA-A110

Automatic Kjeldahl Analyzer LZ-KA-A110

Measuring Range0.1mg ~240mg N Analysis time5 – 10 min/ sample Recovery≥99.5% Samples availableSolid ≤ 5g; Liquid ≤20ml

Automatic Kjeldahl Analyzer LZ-KA-A111

Automatic Kjeldahl Analyzer LZ-KA-A111

Measuring Range0.1mg ~240mg N Analysis time3 – 6 min/ sample Recovery≥99.5% Samples availableSolid ≤ 6g; Liquid ≤16ml

Chemiluminescence Immunoassay Analyzer LZ-CIA-A100

Chemiluminescence Immunoassay Analyzer LZ-CIA-A100

Throughput180T/H Time to First Result18 Minutes Operation ModesRandom, Batch and STAT Sample Positions60 (Each position could be used as an emergency position)

Blood Gas Analyzer LZ-BGS-A100

Blood Gas Analyzer LZ-BGS-A100

SampleWhole blood, Serum, Plasma, Dialysate, CSF Input ParametersPatient Temperature, Hemoglobin, FiO2, B.P. Analysis Time<90s Test ItemspH(CH), pCO2, pO2, K,Na+, CL-, Ca++, Hct, B.P.

Carbon Sulphur Analyzer LZ-CSA-A100

Carbon Sulphur Analyzer LZ-CSA-A100

Measurement RangeCarbon: 0.0001%-95.0000% (can be expanded to 99.9999; Sulfur: 0.0001%-95.0000% (can be expanded to 99.9999%) Analysis TimeAdjustable within 25-60 s (Normally around 35s) Sensitivity0.1 ppm Working GasOxygen, Purity > 99.5%

TOC Analyzer LZ-TOC-A100

TOC Analyzer LZ-TOC-A100

Detection Range1-1500ppb Detection Limit1ppb Maximum Tolerance±5% Analysis Time3min

Laser Particle Size Analyzer LZ-LPSA-A101

Laser Particle Size Analyzer LZ-LPSA-A101

Dispersion TypeDry and Wet PrincipleLaser Diffraction AnalysisMie and Fraunhofer scattering Measurement RangeWet dispersion: 0.01 to 1,200μm; Dry dispersion: 0.1 to 1,200μm

Auto Chemistry Analyzer LZ-ACA-A103

Auto Chemistry Analyzer LZ-ACA-A103

Throughput1200 tests/hour Sample Size1 to 70 µL Reagent quantity10 to 350 µL Sample Positions150 sample positions

TOC Analyzer LZ-TOC-A101

TOC Analyzer LZ-TOC-A101

Measurement Range0 to 100,000 mg/L Detection LimitTC: 50 μg/l Measured ParametersTC, TIC, TOC, NPOC Analysis MethodHigh temperature catalytic combustion

Nano Particle Analyzer LZ-NPA-A100

Nano Particle Analyzer LZ-NPA-A100

Measurement (particle size) range1 nm – 10000 nm Sample concentration0.1 mg/mL – 100 mg/mL Light sourceSemiconductor laser, λ = 532 nm DetectorImported Hamamatsu photomultiplier (PMT)

COD Analyzer LZ-COD-A101

COD Analyzer LZ-COD-A101

Test MethodFast digestion spectrophotometry Detection Range10 to 10000 mg/L Accuracy5% Resolution0.01

Dumas Nitrogen Analyzer LZ-NDA-A100

Dumas Nitrogen Analyzer LZ-NDA-A100

Measure range0.1~500 mg N Sample injector60 positions Sample weightSolid≤1g; Liquid≤1ml Analysis time3-4minutes / piece

Texture Analyzer LZ-TA-A110

Texture Analyzer LZ-TA-A110

Test Range5 kg (Standard); 25 kg, 50 kg (Optional) Accuracy0.0001 g Test Speed0 ~ 50 mm/s (Adjustable) Speed0.001 mm/s

Fiber Analyzer LZ-FBA-A110

Fiber Analyzer LZ-FBA-A110

Measuring Range0.1%-100% Sample Quantity0.5-3g per piece Repeatability≤0.4% (Craw Fiber Content below 10%); ≤1% (Craw Fiber Content above 10%) Maximum Capacity6pcs/batch

Laser Particle Size Analyzer LZ-LPSA-A100

Laser Particle Size Analyzer LZ-LPSA-A100

Dispersion TypeDry and Wet Measurement RangeWet: 0.01-3500µm; Dry: 0.1-3000µm ChannelsWet: 116pcs; Dry: 116pcs Accuracy ErrorWet: <0.5%; Dry: <1.0%

Semi-Automatic Coagulation Analyzer LZ-BCZ-A100

Semi-Automatic Coagulation Analyzer LZ-BCZ-A100

Working PrincipleOptical colorimetric Test MenuPT, APTT, TT, FIB Test Channels2 Wavelength470 nm

Semi-Automatic Coagulation Analyzer LZ-BCZ-A101

Semi-Automatic Coagulation Analyzer LZ-BCZ-A101

Working PrincipleOptical colorimetric Test MenuPT, APTT, TT, FIB Test Channels4 Wavelength470 nm

Halogen Moisture Analyzer LZ-HMA-A104

Halogen Moisture Analyzer LZ-HMA-A104

Capacity120 mg Readability1mg Moisture/Dry Precision0.01% SensorPT1000

Milk Analyzer LZ-MA-A101

Milk Analyzer LZ-MA-A101

Measuring RangeFat: 0.01%-25%; SNF: 3%-15%; Density: 1015-1040kg/m3; Proteins: 2%-7%; Lactose: 0.01%-6%; WaterContent: 0%-70%; Temperature: 1°C-40°C; FreezingPoint: -0.4°C~-0.7°C; Salts: 0.4%~1.5% AccuracyFat: ±0.10%; SNF: ±0.15%; Density: ±0.3kg/m3; Proteins: ±0.15%; Lactose: ±0.20%; WaterContent: ±3.0%; Temperature: ±1°C; FreezingPoint: ±0.001°C; Salts: ±0.05% DisplayLCD display ConnectivityRS232

Semi-Automatic Kjeldahl Analyzer LZ-KA-A112

Semi-Automatic Kjeldahl Analyzer LZ-KA-A112

Measuring Range0.1mg ~200mg N Analysis time5-15 min/ sample (depending on sample) Recovery≥99.9% Repeatability±1%

Semi-Automatic Kjeldahl Analyzer LZ-KA-A113

Semi-Automatic Kjeldahl Analyzer LZ-KA-A113

Measuring Range0.1mg ~240mg N Analysis Speed3-6min/Sample Analysis Time0~60min Recovery≥99.5%

Ultrasonic Milk Analyzer LZ-UMA-A100

Ultrasonic Milk Analyzer LZ-UMA-A100

CapacityUp to 100 samples /hour Measuring RangeWorking 0-10,000,000 cell/ml Cell Size2-30µm Fat0.01-45%

Nano Particle Analyzer LZ-NPA-A101

Nano Particle Analyzer LZ-NPA-A101

Measurement PrincipleElectrophoretic Light Scattering (ELS) Particle Size Range1 – 10,000 nm Zeta Potential Range1-500 mV to +500 mV Measurement Concentration Range0.1mg/ml--100mg/ml (Reference to sample)

Urine Analyzer LZ-UA-A105

Urine Analyzer LZ-UA-A105

Test ParametersUrobilinogen(URO), Bilirubin(BIL), Ketone (KET), Blood (BLD), Protein (PRO), Nitrite (NIT), Leukocytes(LEU), Glucose(GLU), Specific Gravity(SG), PH(pH), Ascorbic Acid(VC), Micro albumin(MAL), Creatinine(CRE), Calcium(CAL) Test PrinciplePhotoelectric colorimetric method Sample VolumeMinimum volume: 3ml Aspiration VolumeLess than 1ml

Automatic Urine Sediment Analyzer LZ-USA-A100

Automatic Urine Sediment Analyzer LZ-USA-A100

Test ParametersNormal RBC, Standing RBC, Dysmorphic RBC, Normal WBC, WBCC, Pus Cell, Hyaline Cast, Granular Cast, WBC Cast , Squamous Epithelial Cell, Normal Epithelial Cell, Sperm, Calcium Crystal, Oxalate Crystal Bacteria, Yeast, Amorphous Urates, Mucus etc. Test PrincipleFlow cell digital imaging technology, medical image fusion technology, artificial intelligence identification technique ChannelsFour channels fixed flow counting cell Sample VolumeMinimum volume:3ml, Aspiration volume:1ml

Blood Gas Analyzer LZ-BGS-A105

Blood Gas Analyzer LZ-BGS-A105

ThroughputResults within 60 seconds after sample aspiration Sample Volume150 µL Display10.4-inch color LCD touchscreen BatteryLithium-ion 14.4 V, 6500 mAh

Halogen Moisture Analyzer LZ-HMA-A105

Halogen Moisture Analyzer LZ-HMA-A105

Maximum Weighing120 g Weighing Accuracy0.005g Moisture Range0.01-100% Control ModeAutomatic, timer, manual

Halogen Moisture Analyzer LZ-HMA-A106

Halogen Moisture Analyzer LZ-HMA-A106

Working principleThermogravimetric method Maximum Weighing120g Weighing Accuracy0.001g Moisture Range0.01%-100.00%

NIR Grain Analyzer LZ-NGA-A100

NIR Grain Analyzer LZ-NGA-A100

Spectral Range680 – 1050 nm Resolution7 nm Transmission Measurement6 mm, 18 mm, 29 mm DetectorSilicon diode array

Urine Analyzer LZ-UA-A110

Urine Analyzer LZ-UA-A110

OperationSemi-automatic Test SpeciesHumans and animals Test CategoriesUrine and water Test Items14 parameters (urine), 14 parameters (water)

Rapid Visco Analyzer LZ-RVA-A100

Rapid Visco Analyzer LZ-RVA-A100

Sample capacity2 to 3 g Viscosity range40 to 12000 CP (80 rpm) Viscosity accuracy±3% (S2000 oil, 5000 CP) Speed range20 to 1000 rpm; Computer controlled and adjustable

Auto Chemistry Analyzer LZ-ACA-A104

Auto Chemistry Analyzer LZ-ACA-A104

Throughput120 tests/hour Sample Capacity2 to 30 µL Sample Positions24 + 5 (original tubes) Reagent Positions54 (27 for 6 mL, 27 for 24 mL)

Fluorescence Immunoassay Analyzer LZ-FIA-A100

Fluorescence Immunoassay Analyzer LZ-FIA-A100

TypeClosed System MethodDry fluorescence immunoassay, quantitative Test formatFluorescence quantitative rapid test cards Test Menu66 parameters

Product added to wishlist This product has been added to your wishlist. View Wishlist