Benchtop Conductivity Meter LZ-BCM-A110

  • Conductivity Measurement Range: 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity Accuracy: ± 1 % F.S.
  • Conductivity Resolution: 0.01, 0.1, 1
  • Conductivity Calibration Solutions: 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
  • Conductivity Calibration Points: 1 - 3 points

Benchtop Dissolved Oxygen Meter LZ-BDO-A100

  • DO Range: 0.0 to 20.00mg/L or ppm
  • DO Accuracy: ± 0.05 mg/L
  • DO Resolution: 0.1mg/L
  • DO Calibration range: 1-2 points

Benchtop pH Meter LZ-BPM-A100

  • pH Range: -1.00 to 15.00 pH
  • pH Accuracy: ± 0.01 pH
  • pH Resolution: 0.01 pH
  • Calibration points: 1-3 points
  • Calibration solutions: USA (pH 4.0/7.00/10.01)
Benchtop pH Meter LZ-BPM-B100
  • pH Range: -2.00 to 20.00 pH
  • pH Accuracy: ± 0.002 pH
  • pH Resolution: 0.01 pH/0.001
  • Calibration points: 1-5 points
  • Calibration solutions: USA
BOD Meter LZ-BOD-A100
  • Range: 0-4000 mg/L
  • Cycle length: 1-30days
  • No. of samples: ≤6
  • Culture bottle volume: 580 ml
  • Data storage: 10-year BOD 5 result value

COD Analyzer LZ-COD-A100

  • Measuring range: (0 ~150)mg/L, (0 ~ 1500)mg/L
  • Accuracy: ±8%
  • Repeatability: 0.03
  • Fluctuation: 6mg/L (20min)
  • Samples: 21

Dissolved Oxygen Controller LZ-DOC-A100

  • Dissolved Oxygen Range: 0.0 to 20.0 mg / l
  • Dissolved Oxygen Calibration points: 1 to 2 points
  • Dissolved Oxygen Accuracy: ± 0.5 mg / l
  • Dissolved Oxygen Resolution: 0.1 mg / L
  • % of Saturation of oxygen range: 0.0 to 200.0 %

Multiparameter Benchtop Tester LZ-WQT-B100

  • Type: Benchtop  
  • Display: Digital
Multiparameter Portable Tester LZ-WQT-A100
  • Type: Portable 
  • Display:  Digital
Pocket Dissolved oxygen tester LZ-PDO-A102
  • Dissolved Oxygen Range: 0.0 to 20.0 mg/L (or ppm)
  • Dissolved Oxygen Accuracy: ± 0.5 mg/L
  • % of Saturation Of Oxygen: 0.0 to 200.0%
  • Sensor Type: Polarographic dissolved oxygen probe
  • % Saturation of Oxygen Accuracy: ± 10 % F.S.

Portable pH meter LZ-PPM-A500

  • pH Range: (-2.00) to 16.00 Ph
  • pH Accuracy: ± 0.01 pH
  • pH Resolution: 0.01 pH
  • Calibration Points: 2 points
  • Calibration Solutions: USA (pH 4.01 / 7.00 / 10.01)

Turbidity Meter LZ-TBM-A100

  • Range: 0 to 1100 NTU, 0 to 275 EBC, 0 to 9999 ASBC
  • Resolution: 0.01 (0 to 99 NTU), 0.1 (100 to 999 NTU), 1 (1000 to 1100 NTU)
  • Accuracy: ±2% (0 to 500 NTU), ±3% (501 to 1100 NTU)
  • Calibration Points: 2 to 5 points
  • Calibration Standards: 0.02, 10, 200, 500, 1000 NTU

Wall Mounted Chlorine Meter LZ-WCM-A100

  • HOCL Measuring Range: 0 to 10.00 mg/L
  • Cl Measuring Range: 0 to 20.00 mg/L
  • pH Range: 0 to 14 pH
  • Temperature range: 0 to 60°C
  • Resolution: 0.001mg/L, 0.01mg/L, 0.01pH, 0.1°C
Water Activity Meter LZ-WTM-A100
  • Range: 0 ~ 0.1 aw
  • Resolution: 0.01 aw
  • Accuracy: ±0.02 aw
  • Sensor: Non conductive humidity sensor
  • Sampling Time: 5mins
Water Hardness Electrode LZ-WHE-A100
  • Concentration Range: 0.05 - 200 mmol/L
  • Slope: 24 - 29 mV/decade
  • pH Range: 2 ~ 11 pH
  • Temperature Range: 5 ~50°C
  • Main Interferences: Ba²⁺, Cd²⁺, Cu²⁺